Model FL3112
22
6.0 Spares & Accessories
6.1 Spare
Parts
When ordering Spare Parts and/or Accessories please contact your nearest General
Monitors’ Representative or General Monitors directly and give the following information.
DESCRIPTION PART NR
Instruction Manual
MANFL3112
IR Detector, CO
2
71064-1
IR Detector, Sun
71064-2
Lamp, IR Source
70596-2
Program Card
71336-1
High Vacuum Grease,
150g Tube
916-078
Test Lamp:
TL105-3-2
Window Cleaning Solution
10272-1
6.2 Test
Lamps
TL103 UV/IR Test Lamp
Due to the advanced discrimination in the Model FL3112, the Model TL103 Test Lamp was
developed. The General Monitors’ TL103 Test Lamp is a battery operated, rechargeable,
test source specifically designed to test General Monitors’ IR Flame Detection Systems. It
consists of a high-energy broad band radiation source which emits sufficient energy in the
infrared spectra to activate the IR detector. To simulate a fire, the test lamp automatically
flashes at one of three DIP switch selectable rates. The Model TL103, rated explosion
proof, is CSA certified for use in Class 1, Division 1, Groups C and D areas. The test lamp
operates on internal lead-acid batteries which, when fully charged, will operate
continuously for 25 to 30 minutes. An internal circuit will prevent operation when the
batteries are low.
Operating Instructions: It is always important to start a series of TL103 checks with a fully
charged unit. Stand within 10 feet of the unit to be tested and aim the TL103 squarely into
the detector face. If the system is operating normally, the detector will go into a WARNing
condition after a few flashes of the Test Lamp. If the lamp remains ON for the time-delayed
period of the DIP switch setting, the detector will go into ALARM. To conserve charge, do
not operate the Test Lamp longer than is necessary to test each detector. When the
battery level drops below the level required to maintain the proper intensity of the lamp, an
internal low voltage circuit will shut the lamp off until the batteries have been recharged.
Recharging Instructions:
Insert the charging plug into the receptacle. Complete
recharging takes a minimum of fourteen hours.
IMPORTANT: Replace the knurled plug after charging is complete.
Charging must be
carried out in a non-hazardous area. The charging receptacle is located inside the housing
adjacent to the ON button. To gain access, it is necessary to unscrew the knurled plug
from the body of the unit. The plug is secured to the ON button by a safety strap to keep it
from being lost. It is recommended that the TL103 be kept on charge when not in use to
prevent excessive battery discharge. The batteries may be charged an average of 500
times and the battery pack is replaceable.
TL105 UV/IR Test Lamp
Please refer to the TL105 Test Lamp manual for operating instructions