Function coil address, readable and writable (read function code is 0x01,
write function code is 0x05)
300
00301
Reset
of
all
parameters
Write:
FF00H
=
valid
(only write FF00H);
Read: 0001H = open
0000 h = closed
301
00302
Partial parameter
reset (all but not
calibration)
302
00303
Calibration
parameter reset
303
00304
Reset of weighing
parameters (basic
parameters
of
transmitter)
304
00305
The reserved
305
00306
Application
parameter reset
306
00307
Clearing
Historical Data
307
00308
Serial
port
Parameter Reset
308
00309
Reset
network
port Parameters
309
00310
GPRS parameters
reset
310
00311
Reset
all
communication
parameters
311-399.
00312-00400.
The reserved
Coil address, readable and writable (read function code 0x01, write
function code 0x05)
400
00401
Input IN1
Bit read-only area, read
bit each input, output
port status, valid 1,
invalid 0
401
00402
Input IN2
402
00403
Input IN3
403
00404
Output the OUT1
404
00405
Output OUT2
405
00406
Output OUT3
406
00407
Custom IO1
407
00408
Custom IO2