Operation
Terminal Interface
3-20
SpectraComm 553 Fractional T1 DSU
076R155-000
Installation and Operation Manual
Issue 7
Figure 3-15
Alarm Threshold Configuration Screen
Diagnostics
The terminal interface SC 553 Diagnostics screen displays three groups of selections that
correspond to the three types of test: T1, Channel, and DS0. Each group includes a command
selection for starting its type of test. The screen also has a selection for setting how long tests run,
and one for specifying the timing source the DSU uses during tests.
When a test begins, the Diagnostics screen shown in
is replaced by the Diagnostics
Results screen shown in
. The Results screen permits you to monitor the progress of the
test procedure while it takes place and displays results at the end of procedures that employ self test.
Instructions for using the screens to perform tests appear in Chapter 4, Tests , together with
descriptions of the diagnostic functions.
ALARM THRESHOLD CONFIGURATION
ALARM
WINDOW
------------------------------------------
[1] Network BPV:
Report All
[2] Network CRC:
Report All
[3] Network LAD:
Report All
[4] Cascade BPV:
Report All
[5] Cascade CRC:
Report All
ALARM
THRESHOLD
-------------------------------------------
[6] Network BPV:
>10
[7] Network CRC:
>10
[8] Network LAD:
>10
[9] Cascade BPV:
>10
[a] Cascade CRC:
>10
[b] Report all global
[0] RETURN TO PREVIOUS MENU
Select: [ ]