7
1.5.6 GENERATOR
Rated Maximum Continuous AC Output at ...
85º F (29º C) Ambient ...............................................8,500 Watts (8.5 kW)
100º F (38º C) Ambient .............................................7,500 Watts (7.5 kW)
120º F (49º C) Ambient .............................................6,000 Watts (6.0 kW)
Rated Voltage .....................................................................120/240 Volts AC*
Rated Maximum Continuous AC Current at ...
8,500 Watts
120 Volts .............................................................................70.8 Amps
240 Volts .............................................................................35.4 Amps
7,500 Watts
120 Volts .............................................................................62.5 Amps
240 Volts ...........................................................................31.25 Amps
6,000 Watts
120 Volts .............................................................................50.0 Amps
240 Volts .............................................................................25.0 Amps
Phase ......................................................................................................Single
Rotor Speed at No Load ..................................................................3,780 rpm
Number of Rotor Poles ...................................................................................2
Engine RPM ............................................................................................ 1,950
Rated AC Frequency ............................................................................... 60 Hz
Battery Charge Voltage ..................................................................14 Volts DC
Battery Charge Current ..............................................................2 Amps (max)
Weight ........................................................................................... 504 Pounds
Length .......................................................................... 36.6 inches (929 mm)
Width ........................................................................... 23.8 inches (604 mm)
Height .......................................................................... 23.8 inches (604 mm)
* All units are reconnectable to 240-volt only AC output.
2.1 GENERATOR CONTROL PANEL
The following features are mounted on the generator control panel
(Figure 2.1):
Figure 2.1 – Generator Control Panel
15 AMP
SYSTEM
CONTROL
STOP
START
PREHEAT
30 SEC. MAX
LINE BREAKER
ON
ON
2.1.1 HOURMETER
This indicates the length of time the engine/generator has operat-
ed, in hours and tenths of hours. Use the hourmeter to ensure that
the periodic maintenance tasks for the generator are completed on
a timely basis.
2.1.2 START/STOP
SWITCH
To crank and start the engine, hold this switch in the START posi-
tion. Release the switch when the engine starts. To stop an operat-
ing engine, press and hold the switch in the STOP position until the
engine shuts off. The switch’s center position is the RUN position.
2.1.3 FUSE
The 15-amp fuse protects the engine’s DC control circuit against
electrical overload. If the fuse element has melted open due to
overloading, the engine cannot be cranked. If the fuse must be
replaced, use only an identical replacement (i.e., AGC-15).
If a fuse element melts, find the cause of the
overload before replacing the fuse.
2.1.4 LINE
BREAKER
The line (i.e., main) breaker protects the generator’s AC output
circuit against overload and provides a method of turning OFF the
generator’s 120/240-volt AC output to the vehicle circuits. The
generator has two 40-amp breakers.
NOTE:
Refer to section “Generator AC Connection System,”. Individual
installations will differ. If an overload occurs, the dual break-
ers will open the ungrounded (i.e., hot) stator leads (11 and
33 in Figure 1.1). When the generator has been connected
for 120/240 dual voltage (Figure 2.16), the line breakers will
operate on the ungrounded (i.e., hot) stator leads (11 and 44
in Figure 2.16).
2.1.5 PREHEAT
SWITCH
The diesel engine is equipped with glow plugs, one for each cylin-
der. When the preheat switch is pressed, the glow plugs heat the
engine combustion chamber, allowing for quicker starts when the
engine is cold. Pressing the preheat switch also operates the fuel
pump.
Operation
Содержание quietpact 85d
Страница 19: ...PART II INSTALLATION INSTRUCTIONS ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION ...
Страница 23: ...21 Figure 1 2 Major Features and Dimensions Drawing 0G6806 A General Information ...
Страница 40: ...38 Electrical Data Schematic 120 240 VAC Output Drawing No 0G7332 C ...
Страница 41: ...39 Schematic 120 240 VAC Output Drawing No 0G7332 C Electrical Data ...
Страница 42: ...40 Electrical Data Schematic 120 240 Dual Voltage Drawing No 0G7333 D ...
Страница 43: ...41 Schematic 120 240 Dual Voltage Drawing No 0G7333 D Electrical Data ...
Страница 44: ...42 Electrical Data Schematic 120 240 Dual Voltage Drawing No 0G7333 D ...
Страница 45: ...43 Schematic 120 240 Dual Voltage Drawing No 0G7333 D Electrical Data ...
Страница 46: ...44 Exploded Views Parts Lists Engine Alternator Starter Assy Drawing No 0G7350 B ...
Страница 48: ...46 Exploded Views Parts Lists Enclosure Drawing No 0G7351 B ...
Страница 50: ...48 Exploded Views Parts Lists Cooling System Drawing No 0G7352 B ...
Страница 52: ...50 Exploded Views Parts Lists Fuel Electrical Systems Drawing No 0G7355 A ...
Страница 54: ...52 Exploded Views Parts Lists Customer Controls Assy Drawing No 0G7356 B ...
Страница 73: ......
Страница 75: ......
Страница 77: ......
Страница 79: ......
Страница 81: ......
Страница 83: ......
Страница 85: ......
Страница 87: ......
Страница 89: ......
Страница 91: ......
Страница 93: ......
Страница 95: ......
Страница 97: ......
Страница 99: ......
Страница 101: ......
Страница 103: ......
Страница 105: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 112: ......