1.4 THE 

GENERATOR

Figure 1.1 – 6kW, V-twin, GT-530 Engine 

(door removed)

Air Filter

External Oil Fill/Dipstick

Control
Panel

Data
Label

Circuit
Breaker

Fuel Inlet
(back)

Fuel
Regulator

Composite
Base

Battery
Compartment

Oil Filter

Exhaust
Enclosure

Engine Oil

Dipstick

Engine

Oil Fill

Figure 1.2 – Data Label Sample

1.5 SPECIFICATIONS

1.5.1 GENERATOR

Fuel Type ....................................................................................... LP vapor only
Rated Voltage .........................................................................................120 VAC
Rated Maximum Load Current (Amps) at 120 Volts (LP)* .............................50.0
Main Circuit Breaker ................................................................................ 50 Amp
Phase ................................................................................................................1
Number of Rotor Poles .......................................................................................2
Rated AC Frequency ....................................................................................60 Hz
Battery Requirement ........................ Group 26R, 12 Volts and 525 CCA Minimum
Weight (unit only in lbs.) ................................................................................387
Enclosure ..................................................................................................... Steel
Normal Operating Range:  This unit is tested in accordance to UL 2200 standards 
with an operating temperature of 20 °F (-29 °C) to 122 °F. (50 °C).  For areas 
where temperatures fall below 32 °F (0 °C), a cold weather kit is highly recom-
mended. When operated above 104º F (40º C) there may be a decrease in engine 
power. (Please reference the engine specifications section).
These generators are rated in accordance with UL2200, Safety Standard for 
Stationary Engine Generator Assemblies; and CSA-C22.2 No. 100-04 Standard 
for Motors and Generators.

1.5.2 ENGINE

Type of Engine ......................................................................................... GT-530
Number of Cylinders ..........................................................................................2
Rated Horsepower @ 3,600 rpm* ...................................................................18
Displacement .............................................................................................530cc
Cylinder Block .........................................................Aluminum w/Cast Iron Sleeve
Valve Arrangement ..................................................................... Overhead Valves
Ignition System ................................................................. Solid-state w/Magneto
Recommended Spark Plug ..................................................................... BPR6HS
Spark Plug Gap ................................................................. 0.76 mm (0.030 inch)
Compression Ratio.......................................................................................9.5:1
Starter .....................................................................................................12 VDC
Oil Capacity Including Filter ..........................................................Approx. 1.7 Qts
Recommended Oil Filter ............................................................. Part # 070185F
Recommended Air Filter ............................................................... Part # 0E9371
Operating RPM............................................................................................2,600
*   Engine power is subject to and limited by such factors as fuel Btu content, ambi-

ent temperature and altitude. Engine power decreases about 3.5 percent for each 
1,000 feet above sea level; and also will decrease about 1 percent for each 6 C 
(10 F) above 16 C (60 F) ambient temperature.

1.6  READY TO RUN

The "Ready to Run" on the display is ready when all of the following 

conditions are true:
1.  The AUTO/OFF/MANUAL switch is set to the AUTO position.
2.  The utility voltage being supplied to the unit is being sensed 

by the PCB. If the utility sense voltage is not connected to the 

unit or if it is below approximately 150-160 volts AC, then 

the system will display the message "No Utility Present". This 

indicates that if the AUTO/OFF/MANUAL switch is placed in 

the Auto position, the generator will start.

3.  No alarms are present, for example, low oil pressure, high 

temperature, etc.

General Information

Содержание EcoGen 6kW

Страница 1: ...enerator Owner s Manual LISTED C US NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION DEADLY EXHAUST FUMES OUTDOOR INSTA...

Страница 2: ...3 Electrical Checks 10 2 4 Generator Tests Under Load 12 2 5 Checking Automatic Operation 12 Operation 12 3 1 Control Panel Interface 12 3 2 Automatic Operation 13 3 3 Sequence of Automatic Operation...

Страница 3: ...mation each indicates is as follows nThis symbol points out important safety information that if not followed could endanger personal safety and or property of others This symbol points out potential...

Страница 4: ...to correct generator operation Do not alter the instal lation or permit even partial blockage of ventilation provisions as this can seriously affect safe operation of the generator The generator MUST...

Страница 5: ...e Consult the local fire department with any ques tions pertaining to fire extinguishers EXPLOSION HAZARDS Do not smoke around the generator Wipe up any fuel or oil spills immediately Ensure that no c...

Страница 6: ...tions For that reason the engine is equipped with the fol lowing systems that protect it against potentially damaging condi tions 1 Low Oil Pressure Sensor 6 Low Battery 2 High Temperature Sensor 7 Un...

Страница 7: ...rs 1 5 2 ENGINE Type of Engine GT 530 Number of Cylinders 2 Rated Horsepower 3 600 rpm 18 Displacement 530cc Cylinder Block Aluminum w Cast Iron Sleeve Valve Arrangement Overhead Valves Ignition Syste...

Страница 8: ...es determine the proper location 1 9 LOCATION nThe engine exhaust fumes contain carbon monoxide which can be DEADLY This dan gerous gas if breathed in sufficient con centrations can cause unconsciousn...

Страница 9: ...the enclosure Annex A Explanatory Material A4 1 4 2 Means of demonstrating compliance are by means of full scale fire test or by calculation procedures Because of the limited spaces that are frequentl...

Страница 10: ...of vegetation Clearance at the top should be a minimum of 48 inches from any structure overhang or projections from the wall The generator should not be placed under a deck or other structure that is...

Страница 11: ...erator con trol panel Remove watches rings or other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of the battery Disconnect chargin...

Страница 12: ...INITIAL START UP NOTE These units have been run and tested at the factory prior to being shipped and do not require any type of break in NOTE This unit comes filled with oil from the factory Check the...

Страница 13: ...Use ARROW keys to scroll and find the first number of your Activation Code Press ENTER to select Repeat this step until all digits have been entered Use ESCAPE to correct previous digits Display Read...

Страница 14: ...vidence of overheat ing etc 9 When testing under load is complete turn OFF electrical loads 10 Set the generator s main circuit breaker to its OFF or OPEN position 11 Let the engine run at no load for...

Страница 15: ...menu is reached This page displays the following options HISTORY STATUS EDIT AND DEBUG See the Appendix Menu System 3 2 AUTOMATIC OPERATION To select automatic operation do the following 1 Make sure t...

Страница 16: ...stops immediately 11 During Auto mode cranking if the remote start contacts OPEN OFF the cranking cycle does NOT abort but continues until complete Once the engine starts it will run for one 1 min ute...

Страница 17: ...shut down The under frequency setting is 55 Hz Internal Fault Shutdown Alarm This alarm cannot be cleared call service dealer Undervoltage Shutdown Alarm If the generator voltage falls below 85 of no...

Страница 18: ...ILL ABOVE THE FULL MARK 5 Install the dipstick 6 Reset the AUTO OFF MANUAL switch to its original position 7 If the generator was running first turn the generator s main circuit breaker back to the ON...

Страница 19: ...AUTO position 8 Dispose of used oil at a proper collection center Repeat steps 2 and 3 for the oil reservoir 4 4 CHANGING THE ENGINE AIR CLEANER See The Generator section for the location of the air c...

Страница 20: ...be followed DO NOT SMOKE when near the battery DO NOT cause flame or spark in battery area Discharge static electricity from body before touching the battery by first touching a ground ed metal surfa...

Страница 21: ...er have a Dealer thoroughly clean dry and inspect the generator If the structure ex home has been flooded it should be inspected by a certified electrician to ensure there won t be any electrical prob...

Страница 22: ...erator control panel Start the unit by moving the AUTO OFF MANUAL switch to MANUAL Allow the unit to warm up thoroughly 8 Stop the unit by setting the AUTO OFF MANUAL switch to OFF 9 Turn on the utili...

Страница 23: ...2Y or 500 hours of operation COOLING Enclosure louvers X X W BATTERY Remove corrosion ensure dryness X X M Clean and tighten battery terminals X X M Check charge state X R EVERY 6 M Electrolyte level...

Страница 24: ...k plug s 2 Clean re gap or replace plug s 3 Fuel pressure incorrect 3 Confirm fuel pressure to regulator is 10 12 water column 0 36 0 43 psi for LP 4 Choke remains closed 4 Verify choke solenoid moves...

Страница 25: ...e same navigation method to select the the desired screen refer to the Menu System diagram 6 1 1 CHANGING SETTINGS EDIT MENU To change a setting such as display contrast go to the EDIT menu and use th...

Страница 26: ...E DEBUG INPUTS OUTPUTS DISPLAYS EDIT CONTRAST LANGUAGE TIME DATE EXERCISE TIME SPEED ESC Press the ESCAPE key to jump back up through the menu levels Use the key to navigate through the menu ENTER Use...

Страница 27: ...Generac Power Systems Inc 25 25 Drawing No 0J1320 B Installation Diagram...

Страница 28: ...26 Generac Power Systems Inc 26 Installation Diagram Drawing No 0J1320 B...

Страница 29: ...Generac Power Systems Inc 27 27 Drawing No 0J1320 B Installation Diagram...

Страница 30: ...T BATTERY VOLTAGE SENSING AC DISTRIBUTION PANEL 120 240V DC DISTRIBUTION PANEL 12V 24V 48V BATTERY 12V 24V 48V INVERTER CHARGER GENERATOR HOUSE HOUSE LOADS HOUSE LOADS 120V 240V CHARGER SUPPLY TWO WIR...

Страница 31: ...29 Drawing No 0J1323 C Oil Make up System...

Страница 32: ...30 Notes...

Страница 33: ...31 Notes...

Страница 34: ...ponsible for contacting a Generac Authorized Warranty Dealer as soon as a problem occurs The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Warranty service...

Страница 35: ...hat part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection 4 below Any such emissions related part repaired or replac...

Страница 36: ...er service does not normally exist without a renewable energy system including an inverter battery bank and alternative energy power source Fuel connections other than conventional utility company sup...

Отзывы: