To carry out the operation successfully, make sure the required electrical connections
(bonnet switch and igntion) are complete.
To activate the procedure proceed as follows:
With the system disarmed, open the bonnet and leave it open
!
.
!
!
!
Turn ignition key “ON-OFF”-“ON-OFF”-“ON-OFF”-“ON”.
At the 4th rotation, leave it “ON”.
.
To confirm it has entered in learn mode, the system gives 2 acoustic signals (1 high and 1 low-
pitched), the turn indicators flash once and the LED turns ON
The following operations must be carried out within 4 seconds otherwise the procedure
is invalidated.
Do not close the bonnet otherwise all previously programmed devices will be deleted as
described in the next paragraph.
!
!
!
!
!
The system is ready to receive the device codes.
;
R
“OFF”.
T
Touch the electronic key to its receptacle each time a device is learned a high-pitched signal
sounds and the status LED turns OFF briefly.
epeat this procedure to program other devices.
Turn ignition key
o confirm the end of the procedure, a low-pitched signal sounds, the turn indicators flash once and
the status LED turns OFF.
13.0 - ADDING NEW DEVICES
PAGE 14 - INSTALLER MANUAL
Storing memory is for 55 devices
If an extra device is added, it automatically deletes the first device stored in the system
memory.
.
!
!
!
!