11.0 - SYSTEM PROGRAMMING
The t
E
able below applies to the system programmed in “standard configuration”.
very time you enter the programming procedure, the alarm resets to the default settings.
FUNCTION
STATUS
LED FLASHES
Disabled
Enabled
Disabled
Disabled
Disabled
Enabled
Disabled
-----
Exclusion of arming/disarming optical signals
Exclusion of arming/disarming acoustic signals
System passive arming
Enabling coded output for self-powered siren
Door input - positive
Hazard warning lights (Optical pulse signal)
Negative output during alarm cycle
For Gemini only, turn ignition key
PAGE 12 - INSTALLER MANUAL
If this function is disabled,
under normal operating conditions, will carry a negative
signal while, during an alarm cycle, there will be a lack of negative.
the BLUE wire,
If the Hazard warning flashers are enabled, optical signals will ONLY switch on during
an alarm condition.
The system BLUE wire MUST be connected to the Hazard switch. In this case, do not
connect the alarm ORANGE wires to the turn indicators (see chapter 7.3)
!
A lack of power during electrical system maintenance, will not affect the programming.
The procedure must be carried out entirely. Every turn of the ignition key
the selected function
and moves up to the next one until the programming procedure is completed.
The programmable features are briefly described below while the programming instructions are
illustrated in the next paragraph
disables
.
11.1 - OPTICAL SIGNALS
If the vehicle already has optical lock/unlock signals, the turn indicators alarm flashes
should be deactivated.
11.2 - ACOUSTIC SIGNALS
11.3 - PASSIVE ARMING
11.4 - ENABL
11.5 - DOOR SWITCH POLARITY SELECTION
11.6 - HAZARD WARNING LIGHTS/SELF-POWERED SIREN
This function activates acoustic signals to confirm system arming (1) and disarming (2).
.
(art. 7725).
This function modifies the alarm input signal (positive or negative) according to the signal generated
This function activates the optical
.
This function arms the system 60” after ignition is switched off and the last door is opened and closed.
If a door is opened during this lapse of time, the procedure is interrupted and will resume when the
door is closed
by the doors switch.
signals according to the connection made; only for vehicles where
hook-up is to the Hazard switch
ING OF SIREN (7725) OUTPUT
This function enables the relative output (20-pin connector, position 13, PINK wire) to activate the self-
powered coded siren
!