Страница 1: ...Made in Italy AC 2784 Rev 05 12 12 UK INSTALLATION AND USE MANUAL 932 SERIES ...

Страница 2: ...7 Negative output s ADDING NEW DEVICES DELETING PROGRAMMED DEVICES SYSTEM RESET TECHNICAL SPECIFICATIONS USER MANUAL INSTALLER MANUAL 3 0 9 0 10 0 11 0 12 0 13 0 0 ONNECTION FOR TURN SIGNALS ACTIVATION 7 1 Standard connections 7 2 Connections for vehicles with separate lines 8 1 Connections and management by CAN BUS line 8 2 Connections to door lock motor unit VEHICLE CODE PROGRAMMING SELF LEARNIN...

Страница 3: ...is confirmed by a siren chirp if feature has been enabled and a flash of the turn indicators The system has a 30 arming delay indicated by the LED turned ON steady When the system is armed the internal volumetric protection and comfort feature can be excluded as follows Show the electronic key to its receptacle the LED will give out a quick flash Close all vehicle doors and press the lock button o...

Страница 4: ...is used for EMERGENCYDISARMING and TOTALDISARMING Touching the electronic key to its receptable disarms and switches off the system which does not rearm when the remote control is used acoustic 30 paragraph 2 9 To restore normal operation touch the electronic key to its receptacle A quick chirp and a flash of the status LED will confirm that the system is back to normal mode 2 9 ALARM MEMORY chirp...

Страница 5: ...ficate is not fully compiled or if the enclosed sale document is missing The guarantee is valid exclusively at authorized GeminiTechnologies S p A Service Centers The manufacturer declines any responsibility for eventual malfunctions of the device or any damage to the vehicle electrical system due to improper installation use or tampering This alarm system is solely intended to be a theft deterren...

Страница 6: ...gative ground LED negative output LED positive output Ignition CAN BUS signal CAN H CAN BUS signal CAN L Positive output with system armed A External sensors negative input Bonnet switch negative input Self powered siren lack of negative during alarm or Hazard warning lights Comfort negative output Additional siren or vehicle horn output negative output during alarm Input for self learning and sys...

Страница 7: ...ystem armed A GREEN BLACK GREEN BROWN WHITE BLACK PINK ELECTRONIC KEY Connection of 933 unit with supplied siren Before carrying out electrical connections disconnect the negative battery terminal Re connect ONLY after completion Red Black Green Brown 1 5 6 7 2 3 4 8 YELLOW BLUE GREEN BLUE YELLO BLACK W Additional siren or vehicle horn negative output during alarm BLUE CAN BUS signal LIGHT BLUE CA...

Страница 8: ...TH SEPARATE LINES 7 3 CONNECTION TO HAZARD SWITCH VEHICLE ELECTRICAL SYSTEM BLUE WHITE ORANGE wire must ONLY be connected if the system is to operate through turn indicators WHITE ORANGE wire must ONLY be connected if the system is to operate through turn indicators Insert nr 6 2 Ampere diodes In the SYSTEM PROGRAMMING menu select Hazard warning lights optical pulse signals Do not make this connec...

Страница 9: ...g via turn indicators flashes Arming via turn indicators flashes and door lock motor unit Arming via turn indicators flashes door lock motor unit and nly connect the alarm system CAN BUS wires to the vehicle CAN line System arming disarming connections must be made to the vehicle door lock motor unit polarity inversion CONNECTIONS TO DOOR LOCK MOTOR UNIT available vehicle www gemini alarm com rest...

Страница 10: ...switches off After a 3 4 seconds the LED starts a flashing sequence count the flashes In this case press 1 the button at the 1st flash which corresponds to number After 4 seconds the LED starts blinking again Press 0 the button at the 10th flash which corresponds to After another 4 seconds the LED flashes the third sequence Press the button at the 3rd flash which corresponds to number 3 Press Pres...

Страница 11: ...the turn indicators and proceed as follows Disconnect the 8 way harness connector from the 8 way alarm connector Turn ignition key ON Connect the 8 way wiring connector to the 8 way alarm connector the LED turns ON steady urn ignition key lose all doors and press the lock button on the original remote control When the turn indicators stop flashing a high pitched acoustic signal confirms the arming...

Страница 12: ...gramming The procedure must be carried out entirely Every turn of the ignition key the selected function and moves up to the next one until the programming procedure is completed The programmable features are briefly described below while the programming instructions are illustrated in the next paragraph disables 11 1 OPTICAL SIGNALS If the vehicle already has optical lock unlock signals the turn ...

Страница 13: ...ning functions When the last function is programmed either with the electronic key or the ignition key in addition to the confirmation tone the system gives 2 low pitched and 1 high pitched acoustic and the turn indicators flash twice These last two signals indicate the end of the programming procedure steps With the alarm system disarmed turn ignition key ON and touch the electronic key to its re...

Страница 14: ...otherwise the procedure is invalidated Do not close the bonnet otherwise all previously programmed devices will be deleted as described in the next paragraph The system is ready to receive the device codes R OFF T Touch the electronic key to its receptacle each time a device is learned a high pitched signal sounds and the status LED turns OFF briefly epeat this procedure to program other devices T...

Страница 15: ...red in the delete mode the system gives 2 acoustic signals 1 high and 1 low pitched the turn indicators flash once and the LED turns ON To clear the memory leave the bonnet closed for at least 8 seconds The following operations must be carried out within 4 seconds otherwise the procedure is invalidated If the bonnet is opened before 8 seconds the devices will not be deleted The status LED turns OF...

Страница 16: ...ashes 15 0 15 1 CO 15 2 SENSOR ADJUSTMENT I T ULTRASONIC VOLUMETRIC PROTECTION NNECTION AND POSITIONING nsert the WHITE connector in the W marked socket and the RED connector in the R marked socket see figure below Install the ultrasonic sensors on the top part of the windshield internal pillars away from the air vents and point them towards the center of the rear window o check the sensitivity le...

Страница 17: ...th system armed and LED flashing Working temperature Turn indicators relay contact capacity Engine immobiliser relay contact capacity Alarm cycle duration Maximum positive current output when armed A Maximum load of siren output range 12 Vdc 15 mA 30 C to 70 C 8 A 20 C 8 A 20 C 30 sec 700 mA 1 A ...

Страница 18: ...7 Dudley Court Jessop Close Clacton on Sea Essex CO15 4LY TEL 44 0 1255 434353 Email sales avsgemini com Web www avsgemini com UK Distributors of the Gemini Alarm Systems ...