Rev. 00 08/17
68
Maintenance / Repairs
MagicControl 4.0 (CM40)
Fig. 67:
3.
Press the
key
The following page is displayed:
Fig. 68: Powder output/powder hose correction
Station
Gun (
activated
/deactivated)
Powder output
Total air
Minimum powder output
Powder hose correction
Changes per gun or all guns at the same time
Exit current page
4.
Set the total air to
4.0
(Nm³/h) on the
(4)
display. Set the powder
output to
0
(%) on the
(3)
display
5.
Check the correction value for minimum powder output
C0
on the
(5)
display, and set it to
1.8
(Nm³/h) if necessary