Rev. 00 08/17
MagicControl 4.0 (CM40)
Start-up
27
Start-up
Preparation for start-up
Basic conditions
When starting up the plant control, the following general conditions
impacting the coating results must be taken into consideration:
–
Gun control units, axes and all other system components correctly
connected
–
Guns correctly connected
–
Corresponding power and compressed air supply available
–
Powder preparation and powder quality
General information
The plant control is pre-parameterized, configured and tested at the
Gema factory. This allows faster commissioning, since fewer parameters
need to be set on site.
The application data in the laboratory report (if available) provides
additional help, and can be used as the basic setting for guns and axes.
The control can be subsequently adjusted and extended.
Changes of correction values may only be made by Gema trained
personnel.
Some of the configurations or settings can be made during operation, for
everything else refer to the "Technical Manual".
Job-related object and process data are managed in the "Coating
programs" menu and in the corresponding submenus.
Depending on the access level of the user who is logged on, parameters
can be edited or only displayed. Some parameters are reserved
exclusively for Gema Service.