User’s & Technical Manual –
ANALOG LIQUID LEVEL SENSOR ALLS6000
GELEC
Industrial Electronics
PAGE
9
6.
ALLS6000 VERSIONS AND OPTIONAL PARTS
ALLS6000-S1 - STANDARD VERSION
●
Mounted potentiometer for level adjustment
●
10kPa air pressure sensor
●
Pre-calibrated
High Level
at 100 cm of clear water
(Programmable
High Level
at points lower than 100 cm)
●
Pre-calibrated
Low Level
at 1cm of clear water (offset)
(Programmable
Low Level
at points higher than 1cm)
●
Differential Level
at 50% of the Target Level,
programmable between 1cm and 100cm
●
Built-in air flow regulator
●
Air pipe connectors (4-6 mm)
ALLS6000-Sx- CUSTOMIZED VERSION
The device can be customised to your application with the following:
●
External potentiometer for the Target Level adjustment
●
Air pressure sensor range from 10kPa to 150kPa
●
Pre-calibrated
High Level
at 100 - 1500 cm clear water
(Programmable High Level at lower than the pre-calibrated
point)
●
Pre-calibrated
Low Level
at a point higher than
1cm of clear
water (offset) (programmable Low Level at higher than the
pre-calibrated point)
●
Pre-calibrated
Differential Level
at any desirable level
between the Low and the High Level)