User’s & Technical Manual –

 

ANALOG LIQUID LEVEL SENSOR ALLS6000 

GELEC

  

Industrial Electronics

 

                                                                                                                                                                       PAGE

 

23

 

ELECTRICAL CONNECTIONS 

 

The  unit  is  equipped  with  two  5mm  pitch  connectors  located  at  the  top 
and bottom. Let some  free space (about 15mm) at both top and bottom 
sides for the wires to be inserted and connected properly. Insert and screw 
only  one  wire  in  each  terminal  in  order  to  be  in  compliance  with  VDE 
norms. 
 
The  cable  may  be  rigid  solid  from  0.2mm

2

  up  to  4.0mm

2

  or  flexible 

stranded from 0.2mm

2

 up to 2.5mm

2

 (24-12AWG) (stranded with ferrule or 

plastic sleeve up to 0.75mm

2

) stripped over 10mm length. 

 

Always follow the instructions given by the manufacturer and use  

the ALLS6000 according to its specifications.

 

 

 

14.

 

ELECTRICAL CIRCUIT DIAGRAM 

 

 

fig. 23

 

 

 

fig. 24

 

Содержание ALLS6000

Страница 1: ...ANALOG LIQUID LEVEL SENSOR ALLS6000 INDUSTRIAL ELECTRONICS...

Страница 2: ...User s Technical Manual ANALOG LIQUID LEVEL SENSOR ALLS6000 GELEC Industrial Electronics PAGE 2...

Страница 3: ...UID LEVEL SENSOR ALLS6000 7 5 GENERAL DESCRIPTION 8 6 ALLS6000 VERSIONS AND OPTIONAL PARTS 9 7 CONTROL UNIT ALLS6000 11 8 PNEUMATIC SECTION 11 9 ELECTRICAL SECTION 14 10 OPERATING PHILOSOPHY LEVEL DES...

Страница 4: ...lectric shock or other damage Do not touch the plug and the connectors with wet hands Disconnect the ALLS6000 before cleaning it to avoid the risk of electric shock Attempting to use a malfunctioning...

Страница 5: ...ial and or faulty construction and functional defects GELEC and authorized distributors will at their option either repair or replace the faulty product with the same or similar model GELEC and author...

Страница 6: ...tes that this should not be treated as household waste when you wish to dispose it It should be handed over to an applicable collection point for the recycling of electrical and electronic equipment B...

Страница 7: ...not touch any part of the ALLS6000 the manual does not cover Keep the manual for immediate reference It should help in solving any operational questions you may have No part of this manual may be quo...

Страница 8: ...to voltage Afterwards several electronic circuits and a microcontroller process this signal and depending on user adjustments a digital command is taken when the liquid in the tank reaches the selecte...

Страница 9: ...50 of the Target Level programmable between 1cm and 100cm Built in air flow regulator Air pipe connectors 4 6 mm ALLS6000 Sx CUSTOMIZED VERSION The device can be customised to your application with t...

Страница 10: ...4 6mm Connectors Air Pipe Nylon air pipe 4 6 mm inner outer Deflation Tube 12mm outer diameter and 120cm length deflation tube divided in two pieces with connection fig 3 fig 4 fig 5 fig 6 fig 7 2 5...

Страница 11: ...mall quantity of air is provided to the tube via air pipes and deflates into the liquid in a form of bubbles The deflation tube must have a 60o V cut at the bottom for proper air deflation and a pipe...

Страница 12: ...ipes are suitable for these connectors Maintain the air purity in an acceptable level Dusty and polluted air makes the pipes dirty and high level of humidity or oil will damage the sensor The P is the...

Страница 13: ...se span and offset bias equalized with the Atmospheric pressure A silicone gel isolates the die surface and wire bonds from the environment while allowing the pressure signal to be transmitted to the...

Страница 14: ...AL OUTPUT Terminals 1 N C 2 COM 3 N O This output terminals 1 2 3 works as a potential contact of a relay These contacts allow the operation of the device that fills drains the tank The DPDT relay con...

Страница 15: ...Level HL Therefore the value that the arrow is pointing is the desirable TL but as a percentage of the HL and not as an absolute value The potentiometer s use during the level calibration process is d...

Страница 16: ...ion process it is essential for the DL also to be modified to the desirable level Working region It is the desirable region which the liquid level fluctuates either in FILLING or DRAINING mode The wor...

Страница 17: ...erential level you have to calibrate Calculate the differential coefficient k between your desirable TL and DL which are the two limits of your working region as below k 100 TL DL TL 1 And then use k...

Страница 18: ...d has the below preselected values and parameters Liquid Soft Water High level HL 100 cm Differential level DL 50 of TL Low level LL 1cm 0 1cm offset NOTES The device measures the hydrostatic pressure...

Страница 19: ...ing mode with the pre existed values HL High Level Calibration Fill the tank up to the highest desirable level fig 15 Press and hold the button until the led starts flashing Turn the potentiometer unt...

Страница 20: ...the calibration process without changing the other two level values 12 FILLING DRAINING OPERATING MODES ALLS600 has two programmable operating modes for liquid level control FILLING MODE and DRAINING...

Страница 21: ...level reaches the DL fig 21 fig 20 fig 21 OPERATING MODE SELECTION F D You can see the mode that the ALLS6000 unit operates by the flashing colour of the LED just after the device power supply Accord...

Страница 22: ...to the cabinet may result to fire electric shock or equipment damage Do not block the ventilated slots above and below the unit If a small object or liquid falls spills into the ALLS6000 cabinet unplu...

Страница 23: ...to be inserted and connected properly Insert and screw only one wire in each terminal in order to be in compliance with VDE norms The cable may be rigid solid from 0 2mm2 up to 4 0mm2 or flexible str...

Страница 24: ...User s Technical Manual ANALOG LIQUID LEVEL SENSOR ALLS6000 GELEC Industrial Electronics PAGE 24 15 AIR CIRCUIT DIAGRAM 16 DIMENSIONS fig 25...

Страница 25: ...EMPERATURE HYSTERESIS 0 5 VFSS full scale span TEMPERATURE EFFECT ON FSS 2 0 2 0 VFSS full scale span OPTIONAL ANALOG OUTPUT RLOAD 450K PWM 0 5V RLOAD 1M LL HL PWM 0 4 5V RLOAD 450K LL HL DIGITAL OUTP...

Страница 26: ...IONS 2 ends 4 6mm Air pipe connectors AIR CONNECTOR TYPE Manually operated AIR PIPE COMPATIBILITY Polyurethane or nylon air pipes HOUSING BOX Semi crystalline thermoplastic polyamide pa 6 6 case INFLA...

Страница 27: ...E ALLS6000 OPTIONS AND VERSIONS This Declaration covers all options and versions of this product Complies with the requirements of the European Directives 89 336 EC 92 31 EEC 73 23 EC 93 68 EEC And th...

Страница 28: ...ical Manual ANALOG LIQUID LEVEL SENSOR ALLS6000 GELEC Industrial Electronics PAGE 28 INDUSTRIAL ELECTRONICS 4 Kikladon Str Maroussi Athens Greece GR 15125 Telephone 30 210 6144074 Fax 30 210 6144074 i...

Отзывы: