background image

7

ENGLISH

Dear Customer, thank you for choosing a GEL descaling – flushing pump. 

MANUAL

This manual is a safe guide for the use of the pump. Please read it 

carefully in all its parts before use. 

This manual contains important information for the proper working and 

use of the equipment. 

GEL reserve the right to introduce any future changes without notice or 

replacement. 

PRELIMINARY INSPECTION

Upon receipt of the pump, take it out from the carton and check it is in 

perfect condition.  Also check that the data on the rating plate correspond 

to required ones. Any anomaly must be advised immediately. 

PRECAUTIONS

Only use GEL chemicals in order to ensure good working and avoid 

damaging the equipments. 

Once the lifetime of the pump has expired, do not dispose of it 

with household waste. The pump must be recycled in 

authorized centres and can be assimilated to a household 

appliance. 

During handling lift the pump and do not drag it in order to avoid damages 

to the tank. 

Temperature of the descaling solution must never exceed 50 °C. 

Flexible hoses and fittings can damage in time; make sure to check the 

seal whenever using the pump, as indicated in the pump preparation 

instructions. 

SAFETY INSTRUCTIONS 

-   Avoid using the pump in places where there are liquids, gases, 

flammable powders or with risk of explosion. 

-  Before plugging in the pump, make sure the switch is off.

-   Only use CE-marked outlets. 

-   Use (CE) approved extensions, only if necessary. 

-   Do not use plug adapters. Do not carry out any modifications to the 

plug nor to the electrical cable.

-   Pump shall always be kept in perfect efficiency. 

-   During maintenance operations, check the switch is off and the plug 

is not connected. 

-   Maintenance operations must be carried out by the authorized 

Technical Assistance Service.

-   Only use GEL original spare parts. 

-   Do not carry out any modifications to the pump if not authorized by 

GEL Technical Department (ask for written authorization).

-   Keep children and unauthorized persons away from the pump. 

-   Keep the pump out of reach of children and unauthorized persons. 

-   Do not use the pump if tired or under the effect of alcohol, medicines 

or drugs.  

-   When using the pump, wear overalls, do not wear jewellery, keep hair 

away from the pump.

-   When handling descaling liquids, be very careful. 

-   It is necessary to use Personal Protection Equipment (PPE). 

-  Equipment can be used by children under 8 years and by people with 

reduced physical, mental, sensorial capacity, or by people without 

experience or the necessary know-how, provided they are supervised 

or have received received adequate training, which should include the 

correct use of the equipment and the risks that may arise from its 

use. 

-  Please ensure that children do not play with the appliance.

-  Cleaning and maintenance are intended to be performed by the user 

and must not be carried by children without supervision.

-  If power cord is damaged, it must be replaced by the manufacturer or 

by technical assistance service or a similarly qualified person, in order 

to avoid any hazard.”

CONTENTS 

1 -  INTRODUCTION ....................................................................................p. 7

2 -  REGULATIONS – CE MARK ................................................................p. 7

3 -  DESCRIPTION........................................................................................p. 8

4 -  TECHNICAL FEATURES ......................................................................p. 8

5 -  CUSTOMER SERVICE ..........................................................................p. 8

6 -  USE ..........................................................................................................p. 8

7 -  CHEMICALS ...........................................................................................p. 11

8 -  CHEMICAL COMPATIBILITY  

LONG LIFE SUPERFLUSH / CHEMICALS ........................................p. 11

9 -  DIRECTIONS FOR DISPOSAL .............................................................p. 11

10 -  WARRANTY TERMS AND AFTER-SALE 

ASSISTANCE CONDITIONS ................................................................p. 11

  1 - INTRODUCTION

With time and, above all, temperature increase, magnesium and calcium 

salts contained in water precipitate in the form of microcrystals and 

settle on metallic surfaces of pipes, plant coils and heat exchangers, thus 

reducing flow rate and thermal efficiency. 

To remove scale deposits it is necessary to circulate inside the pipes, by 

using GEL descaling pumps, the chemicals which react with scale, make 

it soluble and thus removed. GEL produces a wide range of products for 

descaling systems and exchangers according to the materials used.

All products are made up of high quality base materials in order to get the 

best results and operate with the highest safety at the same time. 

2 - REGULATIONS – CE MARK

Declaration of Conformity

The pumps are in conformity with the following European Directives, 

Laws and Regulations:

Low voltage Directive:

73/23/EEC

93/68/EEC

Electromagnetic Compatibility Directive:

89/336/EEC

92/31/EEC

93/68/EEC

93/97/EEC

Directives RoHS and WEEE:

02/98/EEC

02/96/EEC

03/108/EEC

QUALITY 

The pump is built with high-quality acid resistant materials and submitted 

to severe operating tests. 

Follow these instructions to avoid any operating and servicing problems.

Содержание LONG LIFE SUPERFLUSH 40

Страница 1: ...resanantes y desincrustantes ES Haszn lati utas t s Helyre ll t s vizk telen t szivatty k HU CN LONG LIFE SUPERFLUSH 40 Manualeistruzioniusoemanutenzione IT Pompe per lavaggi risananti e disincrostaz...

Страница 2: ...restare la massima attenzione necessario utilizzare i DPI dispositivi di protezione individuali L apparecchio pu essere utilizzato da bambini di et non inferiore a 8 anni e da persone con ridotte capa...

Страница 3: ...il codice il numero dei pezzi desiderati 6 UTILIZZO Disincrostazione con invertitore di flusso Per la disincrostazione delle caldaie e degli scambiatori di calore Riempire il serbatoio con una quantit...

Страница 4: ...rete aperta Scarico aperto Acqua di rete aperta Scarico aperto Acqua di rete chiusa Scarico chiuso Acqua di rete chiusa Scarico chiuso Acqua di rete chiusa Scarico chiuso Fig 3 Fig 4 Fig 5 Fig 6 Fig...

Страница 5: ...isulta essere priva di eventuali residui di prodotto chimico 8 Scaricare la soluzione neutralizzante utilizzata 6 3 PULIZIA DEI NUOVI IMPIANTI CON PRODOTTO CHIMICO LONG LIFE 300 Per effettuare la puli...

Страница 6: ...i glicole etilenico inibito GEL TERMOL 20 Prodotto liquido anticongelante atossico incolore a base di glicole etilenico inibito Pronto all uso per una protezione fino a 20 C 8 COMPATIBILITA CHIMICA LO...

Страница 7: ...overalls do not wear jewellery keep hair away from the pump When handling descaling liquids be very careful It is necessary to use Personal Protection Equipment PPE Equipment can be used by children u...

Страница 8: ...mp item code description and number of pieces desired 6 USE Descaling with flow reverser For descaling boilers and heat exchangers Fill the tank with enough descaling chemical according to the type of...

Страница 9: ...pen Dump open Mains water supply open Dump open Mains water supply closed Dump closed Mains water supply closed Dump closed Mains water supply closed Dump closed Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 7 Circul...

Страница 10: ...ny chemical residues 8 Dump the neutralizing solution used 6 3 CLEANING NEW SYSTEMS WITH CHEMICAL LONG LIFE 300 To clean a new heating system operate as follows 1 Make sure the overflow hose is connec...

Страница 11: ...ng systems 7 3 PROTECTIVE ANTIFREEZE CHEMICALS LONG LIFE 500 Atoxic antifreeze with inhibitor Concentrated antifreeze product with specific inhibitors to control scale and corrosion in heating systems...

Страница 12: ...mables ou risque d explosions Avant de brancher la fiche la prise lectrique s assurer que l interrupteur soit teint La prise de courant doit tre adapt e la fiche de la pompe Ne pas utiliser de fiches...

Страница 13: ...12 11 96 93 97 CEE transpos e par D L n 615 du 12 11 96 Directive RoHS e WEEE 02 98 EEC transpos e par D L n 151 du 25 07 05 02 96 EEC transpos e par D L n 151 du 25 07 05 03 108 EEC transpos e par D...

Страница 14: ...du circuit d sembouer 2 relier le trop plein l gout 3 Brancher le c ble d alimentation une prise de courant 230V monophas 50 Hz 4 Ouvrir le bouchon plac sur le r servoir point n 9 figure 1 pour v rif...

Страница 15: ...l ouverture du bouchon du r servoir pour v rifier le d gagement ventuel de vapeurs g n r es par le d tartrage 5 Positionner les vannes comme indiqu sur la figure 3 ajouter le produit chimique dans le...

Страница 16: ...5 10 minutes environ 8 R p ter les op rations pendant un temps de travail minimum de 2 3 heures 9 Une fois l op ration d assainissement avec le produit chimique termin e ouvrir le d charge pour limin...

Страница 17: ...Nitrique NO HNO3 Acide Sulfurique NO H2SO4 Acide Sulfamique max 15 H3NO3S Eau R gale NO 3 HCl 1 HNO3 Soude Caustique max 10 NaOH 9 INSTRUCTIONS POUR L ELIMINATION Conform ment la Directive WEEE 2002 9...

Страница 18: ...X 22 9 long life superflush 22 1 GEL GEL 2 73 23 CEE 791 18 10 77 93 68 CEE 626 25 11 96 89 336 CEE 476 04 12 92 92 31 CEE 476 04 12 92 93 68 CEE 615 12 11 96 93 97 CEE 615 12 11 96 RoHS e WEEE 02 98...

Страница 19: ...19 3 GEL LONG LIFE SUPERFLUSH 40 4 0 75 230 50 IP 54 Max 50 C 102 18 1 40 40 95 70 19 5 MIN MAX 50 C 230 50 BOILER CLEANER N...

Страница 20: ...1 2 3 4 5 6 8 2 9 Long Life 400 Long Life 410 Long Life 800 Long Life 800 1 2 3 230 50 4 5 6 3 3 4 5 6 7 7 5 10 8 5 10 2 4 6 9 5 10 10 2 3 1 2 230 50 3 4 5 5 1 2 3 4 5 6 7 6 7 6 1 2 3 4 5 6 7 8 9 10...

Страница 21: ...4 5 6 7 Boiler Cleaner N 1 2 Boiler Cleaner N 2 3 3 5 5 6 7 4 2 5 6 5 6 7 6 2 7 8 5 3 LONG LIFE 300 1 2 230 50 3 4 1 1 2 3 4 5 2 6 2 2 1 2 3 4 7 2 8 1 2 5 4 LONG LIFE 710 Long Life 710 1 2 3 230 50 4...

Страница 22: ...0 LONG LIFE 400 LONG LIFE 410 LONG LIFE 710 LONG LIFE 800 STRONG LONG LIFE SEALER LONG LIFE SOLAR 100 20 LONG LIFE SOLAR 200 6 3 LONG LIFE 500 GEL TERMOL AT GEL TERMOL AT 20 20 GEL TERMOL GV GEL TERMO...

Страница 23: ...amables Antes de conectar el enchufe a la toma de corriente asegurase que el interruptor est apagado Usar solo tomas de corriente en conformidad con CE Solo si necesario usar alargadores en conformida...

Страница 24: ...eriales anti cidos de las mejores calidades y son sujetos a rigurosas pruebas de funcionamiento La manutenci n y el funcionamento no crean problemas si se respectan estas instrucciones 3 DESCRIPCI N B...

Страница 25: ...ones 1 Atornillar los terminales de los tubos flexibles a la instalaci n a sanear 2 Conectar lo demasiado lleno al descargue 3 Conectar el cable de alimentaci n a una toma de corriente 230 V monofase...

Страница 26: ...n el tanque 5 Accionar la bomba para unos menutos Agua de red abierta Escape abierto Agua de red abierta Escape abierto Agua de red serrada Escape serrado Agua de red serrada Escape serrado Agua de re...

Страница 27: ...r agua de red controlando de mantener el nivel de l quido entre el indicador de MIN y MAX escrita en el tanque 6 Hacer circular el producto qu mico en el circuito de la instalaci n por circa 5 10 minu...

Страница 28: ...o contactar directamente Vuestro revendedor 10 CONDICIONES DE GARANT A Y ASISTENCIA POST VENTA GEL garantiza que los productos vendidos son sin defectos de proyecto realizaci n y vicios relativos a l...

Страница 29: ...ges ismeret hi ny ban lev szem lyek is haszn lhatj k de kiz r lag fel gyelet mellett vagy olyan megfelel kezel si utas t s birtok ban mely a berendez s biztons gos haszn lat t biztos tani tudja s a f...

Страница 30: ...s MAX k z tt van A V ZK TELEN T OLDAT SOHA NEM HALADHATJA T L AZ 50 C ot R gz tse biztosan a flexibilis kimeneteket a tiszt tand berendez sre Csatlakoztassa a t pk belt 230V 50Hz es ramell t shoz M k...

Страница 31: ...zati csap nyitva Lefoly nyitva V zh l zati csap z rva Lefoly z rva V zh l zati csap z rva Lefoly z rva V zh l zati csap z rva Lefoly z rva 3 bra 4 bra 5 bra 6 bra 7 bra 9 Keringettess k a vegyszert a...

Страница 32: ...rtalmat semleges ts k 7 Ism telj k meg a folyamatot addig amig a lefoly ba r tend v z nem lesz teljesen vegyszermentes 8 Vezess k le a haszn lt semleges t folyad kot 6 3 J RENDSZEREK TISZT T SA LONG L...

Страница 33: ...propil n glikol alap nem m rgez fagy ll folyad k GEL TERMOL AT 20 Szintelen propil n glikol alap nem m rgez fagy ll folyad k inhibitorral K l n sen javasolt olyan f t srendszerek fagyv delm re melyek...

Страница 34: ...18 10 77 93 68 CEE recepita con D L n 626 del 25 11 96 89 336 CEE recepita con D L n 476 del 04 12 92 92 31 CEE recepita con D L n 476 del 04 12 92 93 68 CEE recepita con D L n 615 del 12 11 96 93 97...

Страница 35: ...35 3 GEL GEL 40 4 Hp 0 75 230 V 50 Hz IP 54 50 C 102 l min 18 m 1 F 40 l X 40 x 95 x 70 cm 19 Kg 5 GEL 071 7827240 6 MIN MAX 50 230v 50Hz MAX Bolier Cleaner N...

Страница 36: ...0 di rta perto di rta perto Acqua di rete aperta Scarico aperto Acqua di rete aperta Scarico aperto Acqua di rete chiusa Scarico chiuso Acqua di rete chiusa Scarico chiuso Acqua di rete chiusa Scarico...

Страница 37: ...ig 5 Fig 6 Fig 7 4 2 5 Acqua di rete aperta Scarico aperto Acqua di rete aperta Scarico aperto di usa hiuso Acqua di rete chiusa Scarico chiuso di usa hiuso Fig 5 Fig 6 Fig 7 6 2 7 8 6 3 300 1 2 230V...

Страница 38: ...0 800 100 20 200 7 3 LONG LIFE 500 GEL TERMOL AT GEL TERMOL AT 20 20 GEL TERMOL GV GEL TERMOL 20 20 8 max 20 C2H4O2 max 20 HCl max 100 C6H8O7 NO HF max 25 CH2O2 max 25 H3PO4 NO HNO3 NO H2SO4 max 15 H3...

Страница 39: ...s of repairing and or replacing of the product The after sale assistance service under warranty is always supplied by your Dealer Claims For claims please contact your dealer GEL GEL GEL 50 CE CE GEL...

Страница 40: ...par D L n 476 du 04 12 92 92 31 CEE transpos e par D L n 476 du 04 12 92 93 68 CEE transpos e par D L n 615 du 12 11 96 93 97 CEE transpos e par D L n 615 du 12 11 96 WEEE 02 98 EEC transpos e par D...

Страница 41: ...ng Life 800 6 1 7 2 10 1 8 3 220 230 50 9 4 10 5 11 3 Eauder seau ferm e D charge gout ferm e Fig 3 1 5 10 2 5 10 GEL MIN MAX 5 escaler BOILER CLEANER N 6 1 1 2 3 50 4 9 1 5 1 Eauder seau ouverte D ch...

Страница 42: ...erte Fig 3 Eauder seau ferm e D charge gout ferm e 6 7 6 Eauder seau ouverte D charge gout ouverte Fig 6 1 Boiler Cleaner N 2 1 3 2 2 3 Boiler Cleaner N 4 5 8 Fig 5 Eauder seau ouverte D charge gout o...

Страница 43: ...6 5 10 8 7 5 10 5 10 9 8 2 3 10 7 2 PRODUITS CONDITIONNANTS Adapt pour tous les mat riaux Cuivre Acier Acier inox Aluminium Laiton Etain Alliages l gers Zingu s BOILER CLEANER D E Lliquide s P disinc...

Страница 44: ...Cl Acide Citrique max 100 C6H8O7 Acide Fluorhydrique NON HF Acide Formique max 25 CH2O2 Acide Phosphorique max 25 H3PO4 Acide Nitrique NO HNO3 Acide Sulfurique NO H2SO4 Acide Sulfamique max 15 H3NO3S...

Страница 45: ...45...

Страница 46: ...46...

Страница 47: ...47...

Страница 48: ...Via Enzo Ferrari 1 60022 Castelfidardo AN Italy Tel 390717827 Fax 390717808175 www gel it info gel it export gel it ZCI 01688 REV 05 17...

Отзывы: