![gefran POS-MINI SIEIDrive Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/gefran/pos-mini-sieidrive/pos-mini-sieidrive_instruction-manual_2205768029.webp)
One-axis positioner
—————— Instruction manual ——————
29
5.1.3.6. Check of the manual commands
W
ARNING
!
During this phase of the axis configuration procedure the electronic limit switches
are disabled; be careful while using the manual commands.
•
Set a
JOG
speed equal to 10% of the maximum speed.
•
Send the
JOG+
command.
•
Check that the axis is moving in a positive direction.
•
Send the
JOG-
command.
•
Check that the axis is moving in a negative direction.
5.1.3.7. Check of the axis unit of measure
•
Place the axis in a known mechanical point,
pointA
, near the minimum limit switch.
•
Detect the axis ideal value,
positionA
.
•
Place the axis in a known mechanical point,
pointB,
near the maximum limit switch.
•
Detect the axis ideal value,
positionB
.
•
Measure the distance,
DISTANCE,
between
pointA
and
pointB
•
Check that the measured distance,
DISTANCE,
is equal to
positionB - positionA
Track
lower
limit
Track
upper
limit
Position A
-178.34
Position B
121.66
Point A
Point B
Distance = 300 mm
Distance = Position B - Position A
300 = 121.66 - (-178.34)
+
Positive direction
5.1.3.8. Calibration of the Absolute Encoder
•
Place the axis in the mechanical reference point.
•
Detect the value of the absolute encoder.
•
Write the detected value in the
EAbsQRef
parameter.
•
Save the parameters in Flash.
•
Take the DGFC card first to the READY status and afterwards to the RUN status.
Mechanical reference
Quota absolute encoder = 7 864 932
5.1.3.9. Zero Cycle execution
•
Send the
StartCycle0
command.
•
Check that the zero cycle has been completed in the right way.
Содержание POS-MINI SIEIDrive
Страница 1: ...Instruction Manual SIEIDrive ONE AXIS POSITIONER POS MONO...
Страница 6: ...GEFRAN Instruction manual 6...
Страница 48: ...MANUALE PosMono EN Rev 0 1 16 2 2011 1S5E73...