The positioner can be controlled via the Profibus-DP field bus. This appendix describes the format of the
application interface towards Profibus-DP.
Some of the bytes used for the Profibus-DP communication can be read and written also via a normal
configuration serial channel by stating the suitable IPA. The following points have to taken into consideration:
1.
The reading and writing procedure is formed with words where the bytes are gathered into couples.
2.
Each word can contain from 0 to 15 bits.
INPUT for DGFC
Process Data Channel
IPA
BIT
Bit description
Function description
Byte 0
dInAs0: 1268 0
Select position (Bit 0)
Set point array index to be enabled.
SelectPositionByte
1
Select position (Bit 1)
The values are included between
2
Select position (Bit 2)
1 and 64.
3
Select position (Bit 3)
4
Select position (Bit 4)
5
Select position (Bit 5)
6
7
Byte 1
0
ProcessDataInByte 1
1
2
3
4
5
6
7
Byte 2
dInAs1:1270 0
Positioner enabling
Positioner command word.
ControlAxisByte
1
Hold
See the description in the specific
2
Alarm reset
parameter.
3
Zero cycle start
4
Jog+ movement
5
Jog- movement
6
Movement to the Set Point 1.
7
Movement to a 64-set point
arrray
Byte 3
0
Jog+ movement with a fixed
ProcessDataInByte 3
delta space
1
Jog - movement with a fixed
delta space
2
Movement to the Set Point 2
3
4
5
6
Override set at 100%
7
S-shaped ramp enabling