IST-1408.PA01.02 - Dis.0534045
CE408P / User Manual
Pag. 25/41
GECA S.r.l. - Via E. Fermi, 98 25064 GUSSAGO (BS) - Tel. 030 3730218 - Fax 030 3730228
DELETE (Level 2)
: This item allows you to delete the configuration of
the
Logic
Input
.
To delete the input, press
ENTER
on the relevant item.
Press
ENTER
to confirm. ----------------------------------------------------------------
Then the confirmation window will appear.
Press
ENTER
to confirm or to go back, press
ESC
.-------------------------------
If this procedure is correct, a window notifies you that the operation has
been successful. -----------------------------------------------------------------------
Then the screen returns the beginning of the Delete item management.
MODIFY (Level 2)
: This item allows modifying a Logic input already configured, pressing
ENTER
on the
item. The parameters are modified and saved similarly to the configuration.
DETAILS
: This item allows you to see parameters of a Logic input already configured, pressing
ENTER
on its item.
The voices are the same as the configuration of the Logic Input, are shown entries for the input and
the number of the corresponding output. In case you want to go back, press
ESC
.
You can scroll through them using
and
. Then at the end of the
screen, is also referred to its status, and the enabling status of the Logic
Input.
Finally, selecting the row containing the output number, if it is different
from zero, you can press
ENTER
to view its details. ------------------------------
The items of the details can be scrolled with
and
keys. In
addition, at the end of the screen, displays the status of silencing output.
ZONES
In this submenu is possible to manage the Zones of the sensors,
connected to the unit. -----------------------------------------------------------------
The zones can be used in different ways compatible with the number of
available outputs:
A
- To group more sensors of the same model, and using for all the same
outputs (relay) only configured in the area. In the individual sensors can
only be configured the alarm thresholds, setting the number of outputs to
'0 '. In this case when the sensors belonging to the area, exceed the thresholds set, also how has
been made the choice of operating logic, will trigger the related relay outputs...
B
- To group different models of sensors, placed in the same room or on the same floor. In the
individual sensors can only be configured the alarm thresholds and relays outputs, and in the area is
possible set the relay outputs common to all these sensors.
ENABLE/DISABLE (Level 1)
:
These two items allow you to
enable
or
disable
one or more Zones,
even simultaneously.
Disabled
status is displayed on the main screen, next to the Zone, with asterisks “
*****
”.
The
disabled
Zones, no longer trigger the alarm and fault outputs, associated with them (the
outputs remain in a state of normal operation, and then the alarms associated with them are
not triggered).
DELETE
INPUT N.
1
DELETE
CONFIRM ?
YES = ENTER
NO = ESC
INPUT DETAILS
INPUT
N. 1
ACTIVE
:
LOW
OUTPUT N. :
2
STATE
:
HIGH
ENABLE
:
YES
ZONES
1 ENABLE
2 DISABLE
3 CONFIGURE
4 DELETE
5 MODIFY
6 DETAILS
DELETE
INPUT
N. 1
DELETED