8
99079193583897099 © 03-2022
971.197.00.0(00)
Rectifying malfunctions
The operator can perform the following measures to rectify malfunctions:
• Clean the tap aerator
• Clean the basket filter
• Replace the batteries
• Charge the rechargeable battery for generator operation
These measures are described in the operation manual 970.664.00.0.
Malfunction
Cause
Rectification
Water jet too weak
Tap aerator dirty
▶ Clean the tap aerator. → See operation
manual 970.664.00.0.
Basket filter clogged
▶ Clean the basket filter. → See
operation manual 970.664.00.0.
Pipe pressure too low
▶ Test pipe pressure (0.5–10 bar).
No flush actuation
Pipe pressure too low
▶ Test pipe pressure (0.5–10 bar).
Network failure
▶ Check the power supply.
Batteries dead or rechargeable battery
empty
▶ Replace batteries or charge
rechargeable battery for generator
operation. → See operation manual
970.664.00.0.
Washbasin tap is in cleaning mode (red
LED flashes)
▶ Wait approx. 2 minutes.
Detection distance not set correctly
▶ Optimise the detection distance.
Interfering reflections from the washbasin ▶ Optimise the detection distance.
Solenoid valve defective
▶ Replace the solenoid valve. → See
"Replace the solenoid valve", page 14.
IR sensor defective
▶ Replace IR sensor.
Control electronics defective
▶ Restart the control electronics. → See
Restarting the control electronics.
▶ Replace the control electronics.
Water runs
continuously
Interfering objects in the detection range
▶ Remove objects from the detection
range.
Solenoid valve defective
▶ Replace the solenoid valve. → See
"Replace the solenoid valve", page 14.
IR sensor defective
▶ Replace IR sensor.
Pipe pressure too high
▶ Test pipe pressure (0.5–10 bar).
Control electronics defective
▶ Restart the control electronics. → See
Restarting the control electronics.
▶ Replace the control electronics.
Unwanted flow of
water, either too
soon or delayed
IR window is dirty or wet
▶ Clean or dry the IR window.
IR window scratched
▶ Replace IR sensor.
Detection distance of the IR sensor not
set correctly
▶ Optimise the detection distance.
IR sensor is being adversely affected by
influences in the room (mirrors, metal
surfaces, glass washbasins, etc.)
▶ Restart the control electronics. → See
Restarting the control electronics.
▶ Recalibrate IR sensor. → See Setting
the detection distance of the IR sensor.
Pressure fluctuations in the water net
▶ Install a suitable pressure regulator.
Содержание Piave
Страница 1: ...971 197 00 0 00 GEBERIT WASHBASIN TAPS PIAVE AND BRENTA MAINTENANCE MANUAL...
Страница 45: ...99079193583897099 03 2022 971 197 00 0 00 45 1 1 A 2 45 1 B 2 46 1 C 2 46 1 D 2 47 1 A 1 2...
Страница 46: ...46 99079193583897099 03 2022 971 197 00 0 00 1 B 1 NN 2 1 C...
Страница 47: ...99079193583897099 03 2022 971 197 00 0 00 47 1 D 1 2 1 2 1...
Страница 48: ...48 99079193583897099 03 2022 971 197 00 0 00 2 3 4 3 1 2...
Страница 49: ...99079193583897099 03 2022 971 197 00 0 00 49 3 4 4 4 A 2 50 4 B 2 50 4 C 2 51 4 D 2 51...
Страница 50: ...50 99079193583897099 03 2022 971 197 00 0 00 4 A 1 2 NN 4 B 1 2 NN...
Страница 51: ...99079193583897099 03 2022 971 197 00 0 00 51 4 C 4 D 1 1 2...