1.
Loosen the screws (57).
Fig.32
2.
Lift the sensor module (9) off the base plate.
®
Done
10.4.5 Removing the Solenoid Valves and the Control Plate
Fig.33
Requirement:
•
Pay attention to the correct assignment of cables between the solenoid valves
and the circuit board – solenoid valve (63) must be connected to terminal NC;
solenoid valve (64) to terminal NO.
•
Use only solenoid valves as listed in the chapter "Technical data", see
Chapter 5, Page 19.
Warning!
Long switch-on time and high ambient temperature.
Risk of burns from the solenoid valve
► Allow to cool before dismantling.