Fig.22
2.
Screw the adapter into the actuator (A4.1) and tighten using an a/f 17 open
end spanner.
3.
Complete the T.VIS mounting base (198) with O-rings (29, 101) and a plain
bearing (202).
4.
Screw the mounting base (198) into the actuator (A4) and tighten using a face
spanner.
5.
Screw the switch bar (1) into the adapter (139) and tighten using an a/f 13
open end spanner; torque 2 Nm (1.4 lbft).
6.
Fit the control top (B) over the switch bar (1) and on the actuator.
7.
Tighten the clamps (15) and screws (39) to a torque of 1 Nm (0.7 lbft).
8.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
9.
As internal air guiding is not possible on VESTA valves, connect the air
connection (Y1) on the control top to connection A4.2 on the actuator with an
air hose (L).
10.
Carry out commissioning, see Section 7.2, Page 38.
®
Done.
6.6.7
Fitting to an ASEPTOMAG Valve
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Carry out the following steps:
1.
Place the T.VIS adapter plate (M), with O-rings (M1), on the actuator (A.4)
and secure it with four M5 screws (M.2).
Assembly and installation
Mounting the Control Top to Different Valves
430BAL010747EN_3
36
24.07.2020
Содержание T.VIS P-15
Страница 65: ...Appendix 430BAL010747EN_3 24 07 2020 65...