Hint!
When the colours are swapped, the feedback signals are also
swapped.
6.5.3
Connection Diagram for T.VIS Circuit Board (Bottom)
Fig.16
Explanation of the pin assignment
Plug
positio
n
Connector type
Item no. in the
Spare Parts List
Designation
J1
PicoBlade 5-pin
24
Plug-in connector M12/5-
wire/M20/A-coded
J2
PicoBlade 5-pin
50
Plug-in connector M12/3-
wire/M20/B-coded
J3
PicoBlade 3-pin
9
T.VIS sensor module
J5
PicoBlade 2-pin
64
Solenoid valve NO
J6
PicoBlade 2-pin
63
Solenoid valve NC
J7
PicoBlade 4-pin
6.6
Mounting the Control Top to Different Valves
This chapter describes how the control top T.VIS P-15 is installed and removed
on actuators of different valve types. Observe the following notes when doing so.
Notice
Magnetic fields can influence the position measuring system.
Measured values can be changed.
► Protect the control top from external magnetic fields.
Assembly and installation
Mounting the Control Top to Different Valves
430BAL010747EN_3
24.07.2020
31