ONE 7TS – Maintenance
For instruments equipped with electrical connection, please refer to the wiring diagram, which also shows
the calbration range of the instrument.
Instructions for removal
To remove the pressure gauge (or pressure gauge with transmitter, or pressure transducer) proceed as fol-
lows, with reference to figure 7-28:
- loosen the nuts
(7)
and pull out the pressure gauge complete with flange
(6)
.
- The pressure gauge
(1) and
the flange
(6)
can be separated once the half-rings
(4)
have been removed.
FIG. 7- 28
page 7.57