Safety
Residual Risk
18
Operating Instructions · ECOVENT
®
Valve N/W and N.M DN 10/15
Edition 2014-07-04
Residual Dangers
Dangerous situations can be avoided by safety-conscious and proactive behaviour of
the staff and by wearing personal protective equipment.
Residual dangers on the valve and measures
Danger
Cause
Measure
Danger to life
Inadvertent switch-on of the valve
Effectively disconnect all components, effectively prevent
switch-on.
Electric power
Observe the following safety rules:
1
Isolate from the power supply.
2
Take appropriate measures to prevent switch on.
3
Test absence of voltage.
4
Earthing and short-circuiting.
5
Cover or safeguard any adjacent live parts.
Spring tension in the actuator
Danger to life caused by compression spring in the actu-
ator. Do not open the actuator but return it to GEA Tuchen-
hagen for proper disposal.
Danger of injury
Danger presented by moving or
sharp-edged parts
The operator must exercise caution and prudence.
For all work:
•
Wear suitable work clothing.
•
Never operate the machine if the cover panels are not
correctly fitted.
•
Never open the cover panels during the operation.
•
Never reach into openings.
As a precautionary measure, wear personal protective
equipment in the vicinity of the valve:
•
Protective gloves
•
Safety shoes
Environmental
damage
Operating materials with properties
which are harmful to the environ-
ment
For all work:
•
Collect lubricants in suitable containers.
•
Dispose of lubricants in accordance with the pertinent
regulations.
Содержание ECOVENT N/W
Страница 1: ...Operating Instructions ECOVENT Valve N W and N M DN 10 15 Edition 2014 07 04 English...
Страница 55: ...55...