Maintenance
Removing the Valve
30
Operating Instructions · ECOVENT
®
Valve N/W and N.M DN 10/15
Edition 2014-07-04
Maintenance Intervals
To ensure the highest operational reliability of the valves, all wearing parts should be
replaced at longer intervals.
The actual maintenance intervals can only be determined by the user since they depend
on the operating conditions, for instance:
•
daily period of use,
•
switching frequency,
•
type and temperature of the product,
•
type and temperature of the cleaning solution,
•
ambient conditions.
Removing the Valve
Requirement
Make sure that during maintenance and repair work no process is in operation in the
area concerned.
Carry out the following steps:
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean or rinse
them.
2.
Shut off the control air supply.
3.
Disconnect the power supply.
4.
Take the valve, with all housings and housing connections if possible, out of the pipe
section.
Done.
Maintenance Intervals
Applications
Maintenance Intervals
(guideline values)
Media at temperatures of
60 °C to 130 °C
approx. every 3 months
Media at temperatures of
< 60 °C
approx. every 12 months