Operating
Agitating mode (optional)
2008-9015-001
01-2017
7.4
Agitating mode (optional)
Attention!
Stop the motor of the pump before switching from agitation mode to
transfer mode and vice-versa.
Make sure all control levers are locked at desired position before
starting the motor.
STEP #1: Set the directional valve in agitation mode
● Unscrew the locking handle (1);
● Pull up the valve control lever (2);
● Tighten the locking handle (1) into
agitation position.
2
1
STEP #2: Set the agitation nozzle direction
4
3
● Unscrew the locking handle (3);
● Turn the nozzle direction control handle (4) in the desired direction;
● Tighten the locking handle (3) in position.