Technical Data
Hydraulic hoses
2008-9015-001
01-2017
4.5
Control panel specifications
The control panel must:
● comply with the following requirements:
2006/95/CE directives (Electrical equipment designed for use within certain voltage limits)
92/31/CEE directives (Electromagnetic compatibility)
● comply with the following harmonized standards:
EN 60204-1 (Safety of machinery - Electrical equipment of machines);
EN 61082-1 (Documents used in electrotechnology);
EN 60617 (Graphical symbols).
● be equipped with an emergency stop.
● be protected by a lockable disconnect switch (cut-off switch).
● meet all motor specifications provided in this manual.
● meet local electrical requirements.
Special specifications:
● The control panel protection devices must be designed to avoid any
unexpected start.
4.6
Acoustic emission
Noise level
85 dBA
4.7
Hydraulic hoses
Outside diameter (A)
0.56 [14.22mm]
Inside diameter (B)
¼” [6.35mm]
Maximum working
pressure
6000 psi [414 bar]
Minimum burst pressure
24 000 psi [1655 bar]
Feature
High pressure
Construction
Nitrile - Type C
Number of braids
2 braids high-tensile
steel wire