General Programming
6-19
September 2007
PRESSURE/BACKGROUND
GRID Option (cont.)
Note:
The
# Curves
prompt repeats until all of the grids specified in
the
# Grids
prompt have been programmed. Then, you are
returned to the
Calibrate System
menu.
The next prompt appears only if the
Display Background Gas
option
is enabled in the
Set Background Display
branch of the Advanced
Menu (see Chapter 7,
Advanced Programming
). The
Curve #n
prompt allows you to enter a fixed background gas concentration for
one of the curves in the current pressure grid.
Note:
The
gas type
displayed in the
Curve #n
prompt is specified in
the
Select Gas Type
option of the
Advanced Menu
. The
choices are
%Bkgd
(generic),
%H2
,
%N2
(used as an
example in this manual),
%SO2
, and
%CO2
. Refer to Chapter
7,
Advanced Programming
, for more details.
The
Curve #n
prompt repeats until the %N2 values for the total
number of curves specified at the
# Curves
prompt have been entered.
After all the %N2 values have been entered, the
# Points
prompt lets
you specify the total number of data points to be entered for each
curve of the current pressure grid.
The
Point #n
prompt lets you enter the % oxygen for one of the data
points on the calibration curves for the current grid.
Note:
The
gas type
displayed in the next prompt is specified in the
Select Gas Type
option of the
Advanced Menu
. The choices
are
%O2
(used as an example in this manual),
%H2
,
%N2
,
%SO2
, and
%CO2
. Refer to Chapter 7,
Advanced
Programming
, for more details.
CALIBRATE GRID #N
To accept the current value, press
[Y]
or
[Enter]
. To change the
current value, use the numeric
keys to enter a new value and
press
[Y]
or
[Enter]
twice.
# Curves [x]:
Curve #n
To accept the current value, press
[Y]
or
[Enter]
. To change the
current value, use the numeric
keys to enter a new value and
press
[Y]
or
[Enter]
twice.
%N2 [xx.x]:
CALIBRATE GRID #N
To accept the current value, press
[Y]
or
[Enter]
. To change the
current value, use the numeric
keys to enter a new value and
press
[Y]
or
[Enter]
twice.
# Points [x]:
Содержание XMO2
Страница 8: ...Chapter 1 ...
Страница 18: ...Chapter 2 ...
Страница 30: ...Chapter 3 ...
Страница 41: ...Chapter 4 ...
Страница 52: ...Chapter 5 ...
Страница 66: ...Chapter 6 ...
Страница 114: ...Chapter 7 ...
Страница 146: ...Chapter 8 ...
Страница 159: ...Appendix A ...
Страница 165: ...Appendix B ...
Страница 167: ...September 2007 Outline and Installation Drawings B 1 Figure B 1 Outline and Installation ref dwg 712 1008B ...
Страница 168: ...September 2007 Outline and Installation Drawings B 2 Figure B 2 XMO2 Assembly ref dwg 705 677H ...
Страница 171: ...September 2007 Outline and Installation Drawings B 5 Figure B 5 Digital PCB Assembly ref dwg 703 1139 ...
Страница 172: ...September 2007 Outline and Installation Drawings B 6 Figure B 6 Digital PCB Schematic ref dwg 700 1139 sht 1 ...
Страница 173: ...September 2007 Outline and Installation Drawings B 7 Figure B 7 Digital PCB Schematic ref dwg 700 1139 sht 2 ...
Страница 174: ...September 2007 Outline and Installation Drawings B 8 Figure B 8 Analog PCB Assembly ref dwg 703 1138 ...
Страница 175: ...September 2007 Outline and Installation Drawings B 9 Figure B 9 Analog PCB Schematic ref dwg 700 1138 sht 1 ...
Страница 176: ...September 2007 Outline and Installation Drawings B 10 Figure B 10 Analog PCB Schematic ref dwg 700 1138 sht 2 ...
Страница 177: ...Appendix C ...