20
49-2000707 Rev. 5
INST
ALLA
TION INSTRUCTIONS
Installation Instructions
4
(Alternate Mounting Method) INSTALL HOOD TO SOFFIT OR CABINET
(Cont.)
• Drill two 1/8” pilot holes at a distance of 10” from the
back wall in the horizontal wood supports. This is the
vertical distance between mounting keyholes and
back wall as shown in Figure C
• Drill two more 1/8” pilot holes at a distance of 3” from
the back wall in the horizontal wood supports. This is
the vertical distance between mounting screw holes
and back wall as shown in Figure C.
• For top venting, allow minimum opening (Dim. B) to
accommodate damper in soffit or cabinet.
• For back venting, allow minimum opening (Dim. C) to
accommodate damper in back wall.
3”
Figure C
Back Wall
10"
A
Keyholes
for Soffit
or Cabinet
Mounting
• Drive mounting Screw (A) into the studs until they
protrude 1/4”. This 1/4” gap will provide clearance to
engage the keyhole slots in the top of the hood.
• The hood must also be secured to the back wall.
Follow instruction on page 18, “
Drill Bottom
Mounting Hole Locations
” for installation to the
back wall.
• Follow instructions on page 17 "
House Wiring
Locations
" for wiring setup.
• Lift hood onto mounting screws. Slide back against
the rear wall.
• Pull house wiring through the knockout at the rear or
top of the hood.
• Tighten mounting screws (A).
• Once the hood is secured to the soffit or cabinet,
drive screws (C) to secure the hood to the back wall.
1/4” Gap
Soffit or Cabinet
Back
Wall
Engage Keyhole Slots
and Push Back at Wall