B.4 MEMORY MAPPING
B
CB21
Remote Device 1 GOOSE Ethernet APPID
0 to 16383
---
1
F001
0
CB22
Remote Device 1 GOOSE Dataset
0 to 16
---
1
F184
0 (Fixed)
CB23
Remote Device 1 in PMU Scheme
0 to 1
---
1
F126
0 (No)
CB24
...Repeated for Device 2
CB48
...Repeated for Device 3
CB6C
...Repeated for Device 4
CB90
...Repeated for Device 5
CBB4
...Repeated for Device 6
CBD8
...Repeated for Device 7
CBFC
...Repeated for Device 8
CC20
...Repeated for Device 9
CC44
...Repeated for Device 10
CC68
...Repeated for Device 11
CC8C
...Repeated for Device 12
CCB0
...Repeated for Device 13
CCD4
...Repeated for Device 14
CCF8
...Repeated for Device 15
CD1C
...Repeated for Device 16
Remote Inputs (Read/Write Setting) (32 modules)
CFA0
Remote Input 1 Device
1 to 32
---
1
F001
1
CFA1
Remote Input 1 Bit Pair
0 to 96
---
1
F156
0 (None)
CFA2
Remote Input 1 Default State
0 to 3
---
1
F086
0 (Off)
CFA3
Remote Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
CFA4
Remote Input 1 Name
1 to 64
---
1
F205
“Rem Ip 1”
CFAA
...Repeated for Remote Input 2
CFB4
...Repeated for Remote Input 3
CFBE
...Repeated for Remote Input 4
CFC8
...Repeated for Remote Input 5
CFD2
...Repeated for Remote Input 6
CFDC
...Repeated for Remote Input 7
CFE6
...Repeated for Remote Input 8
CFF0
...Repeated for Remote Input 9
CFFA
...Repeated for Remote Input 10
D004
...Repeated for Remote Input 11
D00E
...Repeated for Remote Input 12
D018
...Repeated for Remote Input 13
D022
...Repeated for Remote Input 14
D02C
...Repeated for Remote Input 15
D036
...Repeated for Remote Input 16
D040
...Repeated for Remote Input 17
D04A
...Repeated for Remote Input 18
D054
...Repeated for Remote Input 19
D05E
...Repeated for Remote Input 20
D068
...Repeated for Remote Input 21
D072
...Repeated for Remote Input 22
D07C
...Repeated for Remote Input 23
D086
...Repeated for Remote Input 24
D090
...Repeated for Remote Input 25
D09A
...Repeated for Remote Input 26
D0A4
...Repeated for Remote Input 27
D0AE
...Repeated for Remote Input 28
D0B8
...Repeated for Remote Input 29
D0C2
...Repeated for Remote Input 30
D0CC
...Repeated for Remote Input 31
Table B–10: MODBUS MEMORY MAP (Sheet 61 of 65)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание UR T60
Страница 10: ...x T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 14: ...xiv T60 Transformer Protection System GE Multilin 0 1 BATTERY DISPOSAL 0 BATTERY DISPOSAL 0 ...
Страница 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 436: ...5 298 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 492: ...8 18 T60 Transformer Protection System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 510: ...9 18 T60 Transformer Protection System GE Multilin 9 6 COMMISSIONING TEST TABLES 9 COMMISSIONING 9 ...
Страница 678: ...C 30 T60 Transformer Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 688: ...D 10 T60 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Страница 700: ...E 12 T60 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...