3900/3900P User’s Manual
4-4
SpO
2
mode printed data
P
I
r
mode printed data
90-100
85-89
80-84
70-79
0-6 9
67
0
33
0
0
0 20 40 60 80 100 %
12:34 80
12:34 82
12:34 84
12:35 86
12:35 88
12:35 90
95
95
80
↓
80
↓
95
95
4
1
3
5
4
SpO
2
90-100%
00:00:24
85-89%
00:00:00
80-84%
00:00:12
70-79%
00:00:00
0-69%
00:00:00
12:34 1.50
12:34 1.50
12:34 0.50
12:35 0.50
12:35 1.50
12:35 1.50
95
95
80
80
95
95
>2.0
1.01-2.0
0.51-1.0
0.26-0.5
0.0-0.25
0
67
0
33
0
0 20 40 60 80 100 %
>2.0
00:00:00
1.01-2.0
00:00:24
0.51-1.0
00:00:00
0.26-0.5
00:00:12
0.0-0.25
00:00:00
TIME PER PI
r
RANGE
2
5
H GONZALES
110
DR CASEY
GENERAL
BY:---------------------
COMMENTS:---------------
------------------------
------------------------
STUDY DATE:
05/16/98
ALARM LEGEND
HIGH SpO
2
..............
↑
LOW SpO
2
...............
↓
NO SENSOR..............!
SENSOR OFF.............?
6-SECOND FORMAT
% TIME PER SpO
2
RANGE
TIME
♥
50 60 70 80 90 100 SpO
2
STUDY DURATION AND VALUES
START DATE/TIME:
O5/16/98 12:34
END DATE/TIME:
05/16/98 12:35
STUDY DURATION:
00:01:00
TIME
LOW SpO
2
80%
84
♥
12:35
HIGH PR
90
♥
LOW PR
80
♥
AVERAGE SpO
2
90%
SpO
2
STD.DEV. ---
SUMMARY STATISTICS
TIME PER SpO
2
RANGE
# SpO
2
VALUES BELOW 85%:
2
TOTAL DURATION BELOW 85%:
00:00:12
H GONZALES
110
DR CASEY
GENERAL
BY:---------------------
COMMENTS:---------------
------------------------
------------------------
STUDY DATE:
05/16/98
6-SECOND FORMAT
STUDY DURATION AND VALUES
START DATE/TIME:
O5/16/98 12:34
END DATE/TIME:
05/16/98 12:35
STUDY DURATION:
00:01:00
TIME
LOW SpO
2
80% 84
♥
12:35
HIGH PR
90
♥
LOW PR
80
♥
AVERAGE SpO
2
90%
SpO
2
STD.DEV.
---
LOW PI
r
0.50 12:35
HIGH PI
r
1.50 12:35
AVERAGE PI
r
1.17
PI
r
STD. DEV.
---
% TIME PER PI
r
RANGE
SUMMARY STATISTICS
PI
r
™ PULSATILE VALUE
TIME PI
r
0.0 1.0 2.0 SpO
2
Figure 4-3. Printed data samples
1
Custom patient label text entered for this data record
2
Symbols used in the SpO
2
graph to indicate alarm types
3
Output interval selected for this data record (6 or 30 seconds)
4
Graphic and numeric patient data (omitted when STATS ONLY was selected)
5
Summary statistics data
Содержание TruTrak+ 3900
Страница 1: ...GE Healthcare 3900 3900P Pulse Oximeter TruTrak User s Manual ...
Страница 2: ......
Страница 3: ...GE Healthcare 3900 3900P Pulse Oximeter TruTrak User s Manual 6050 0006 406 March 2005 ...
Страница 26: ...3900 3900P User s Manual 1 16 ...
Страница 80: ...3900 3900P User s Manual 5 18 ...
Страница 96: ...A 4 3900 3900P User s Manual ...
Страница 102: ...3900 3900P User s Manual B 6 ...
Страница 106: ...Index ...