No Battery Usage
The ASLP11 has no support for a battery to keep the date and time
information. The setup information is stored automatically within an onboard
EEPROM and is updated via standard BIOS Setup function. No external
software is needed to create a user defined setup like in earlier products from
GE Intelligent Platforms.
Environmental conditions
Ambient temperatures and humidity values for the ASLP11:
Table 15: Environmental values
C
-Style
I-Style
High Temperature
-
Storage
-
Operating (see diagram below)
+85 °C
+85 °C
Low Temperature
-
Storage
-
Operating
-40 °C
0 °C
-40 °C
-40 °C
Temperature Shock
-
Storage
-
Operating
+/-10 °C/min
+/-5 °C/min
+/-20 °C/min
+/-10 °C/min
Relative Humidity
-
Storage, Operating
Up to 95 %, non-condensing
Table 16: Shock and vibration values for the ASLP11
C-,
I-Style
Vibration
-
Spectrum
-
Acceleration
5 to 100 Hz
2 g
Shock
-
Amplitude
-
Duration
12 g
6 ms
Table 17: Maximum height usage
C-,
I-Style
Maximum height
-
Operating
-
Storage
4.5 km
12 km
GE Intelligent Platforms – ASLP11 Hardware Reference Manual, Third Edition