DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL
Page
44
Revised May 2003
PUMP
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-103
“SPEED 3” switch closed with the key
turned off.
This status code will be displayed when the “SPEED
3” switch closes while the key switch is turned off.
MEMORY RECALL
NO
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
“SPEED 3” switch is closed or shorted
to battery negative.
·
Verify connections at P20 and
Battery negative. Replace switch,
if necessary.
12
19
20
21
51
*
*
S
PEED
2
S
PEED
1
52
53
*
SPEED
3
*
SPEE
D
4
7
AC
C
E
LE
R
A
T
O
R
SW
IT
C
H
*
BATT
NEG
SX-
2
CONT
RO
L
PL
UG
PL
2
PUMP
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-104
“SPEED 4” switch closed with the key
turned off.
This status code will be displayed when the “SPEED
4” switch closes while the key switch is turned off.
MEMORY RECALL
NO
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
“SPEED 4” switch is closed or shorted
to battery negative.
·
Verify connections at P21 and
Battery negative. Replace switch,
if necessary
.
12