– 53 –
6. Lift the front of the aluminum plate up and
disconnect the ground wire.
Ground Wire
Thermal Cut-out
The thermal cut-out is located between the
fi
ns of
each generator board heat sink and is connected
to the
fi
lter board with a wire harness. The location
of the thermal cut-out allows it to sense an over-
temperature condition of the generator board.
The thermal cut-out has a resistance value of less
than 1
Ω
and opens at approximately 250°F. An
open thermal cut-out will stop operation of the
cooktop. If the thermal cut-out is open, check for
proper operation of the fan and possible vent
obstructions.
Thermal Cut-out
Disconnect
Induction Module
To remove the induction module:
Remove the cooktop elements. (See
1.
Cooktop
Elements
.)
Mark and disconnect the 3 wire harnesses from
2.
the bridge board.
Remove the plastic wire tie from the aluminum
3.
plate.
4. Fold back insulation and place the
fi
lter-to-
bridge board and cooling fan harnesses inside
the module.
5. Remove the 12 Phillips-head screws that attach
the module to the aluminum plate.
Cooling Fan
Harness
Filter-to-Bridge
Harness
Disconnect
Disconnect
Disconnect