9. Disengage the hook of the left side wire
insulation retainer from the frame of the range.
10. Disconnect the 2 wires from the bake element.
11. Using rubber gloves to protect your hands,
carefully grasp the bottom of the insulation,
which covers the side of the range, and tuck the
insulation up under the bottom of the induction
module air inlet vent.
12. Remove the 1/4-in. hex-head screw and the
ground wire from the bake element.
13. Remove the 1/4-in. hex-head screw from the left
side of the element retainer.
14. Using a small
fl
at blade screwdriver, pry the left
side of the retainer away from the element.
16. Grasp the bake element on both sides and
gently pull it toward you as you remove it from
the element tray.
15. Pull the retainer to the left, and disengage the
tab from the slot in the element tray.
Element Tray
Left Side Retainer
Disconnect
Disconnect
Module Inlet Vent
Tab
Note:
When installing the air tunnel, make sure the
•
2 bottom legs are hooked into the slots in the
range frame.
Upon reassembly, ensure displaced insulation
•
around oven and components is returned to its