27
Installation Instructions
AttACHInG A BloWEr trAnSItIon
DuCt
Use a blower transition duct for all downward duct
installations to connect to 6" round standard ductwork .
This 3
1
⁄
4
” x 10" rectangle to 6" round transition duct is
available at your local building supply store .
Install the transition duct to the blower outlet . Secure
all joints with duct tape to assure an airtight seal .
Screws
Screw
(on other
side)
13
ConnECtInG tHE DuCtWorK
Connect the ductwork prepared in Steps 5 and 6
to the blower transition duct .
14
InStAllInG tHE CooKtoP
InStAll tHE PrESSurE rEGulAtor
• For all connections, use a pipe sealant approved by local
codes and resistant to the activity of LP gas .
• Install the pressure regulator in the gas line as close to the
cooktop inlet as possible to allow clearance for ventilation
ducting .
• Make sure the arrow on the body of the regulator is pointing
straight up and toward the cooktop . Any other position
will affect the output pressure of the regulator . This arrow
indicates correct flow of gas .
• Install a manual gas line shut-off valve in an easily accessible
location .
15
Regulator
Solid piping or
flexible connector
Union
Pipe stub
Solid piping
or flexible
connector
Shut-off
valve
InStAll tHE PrESSurE
rEGulAtor (cont.)
notE:
Instead of using solid piping to connect to pressure
regulator, an approved flexible metal appliance connector
may be used between the shut-off valve and the pressure
regulator, if local codes permit .
Appropriate flare nuts and adapters are required at each
end of the flexible connector .
tESt For lEAKS
WArnInG:
Do not uSE A FlAmE to CHECK
For GAS lEAKS!
Do not use the cooktop until all connections
have been leak tested .
Perform leak test per the following instructions:
1 . Purchase a liquid leak detector or prepare a soap solution
of one part water, one part liquid detergent .
2 . When all connections have been made, make sure all
cooktop controls are turned to
oFF
and turn the gas supply
valve to
on
.
3 . Apply the liquid leak detector or the soap solution around
all connections from the shut-off valve to the cooktop .
4 . A leak is identified by a flow of bubbles from the area of
the leak .
5 . If a leak is detected, turn the gas supply
off
. Tighten the
fitting . Turn the gas on and test again .
If the leak persists, turn the gas supply
off
and contact
your dealer for assistance . Do not attempt to operate
the cooktop if a leak is present .
ImPortAnt:
Disconnect the cooktop and the individual
shut-off valve from the gas supply piping system during
any pressure testing of that system at test pressures
greater than 1/2 psig . Isolate the cooktop from the gas
supply piping system by closing the individual manual shut-
off valve to the cooktop during any pressure testing of the
gas supply piping system at test pressures equal to or less
than 1/2 psig .