LOCATION 18 - A/C DELAY AND DYNAMIC BATTERY TEST (2 segments, feature selection data)
Location 18 is used to enable the A/C delay and the dynamic battery test, both of which are timed in
minutes. The factory default is 5-0, meaning the A/C power will be off for 5 minutes before a report
is sent or a service indication will be given, and the dynamic battery test is disabled (“0” minutes). If
you desire the A/C delay to be 8 minutes and the dynamic battery test to be 3 minutes, you would
program 8-3.
LOCATION 19 - DEVICE OPTIONS (8 segments, feature selection data)
Location 19 is used to enable various system features of the NX-320-I power supply.
Option
Function
ON
AC report always
sent
1
OFF Follows
control
panel
If enabled, an AC Fail report will be sent if power is lost for the
time programmed in location 18. If “off”, the report will only be
sent if the control panel has not sent an AC power lost report,
and AC fail report is enabled in location 37 of the control
panel.
2
ON
Enables periodic battery test.
Enables battery missing every 30 seconds.
3
ON
Enables low battery test.
If enabled, the NX-320-I will report low battery to the central station.
4 ON Enables
siren
tamper/trouble reporting.
If enabled, the NX-320-I will report a siren tamper to the central station.
5-8
Reserved
NX-320-I Programming worksheets
(Defaults are printed in
bold italic
text)
At default: Output A = AUX power, Output B = AUX power, Output C = smoke power
LOC
DESCRIPTION
DEFAULT
PROGRAMMING DATA
0
OUTPUT A: EVENT & TIME
0 10
OUTPUT A: SPECIAL FEATURES & PARTITIONS
Segment 1
(Circle Numbers To Program)
1
ON: if timed in minutes. OFF: if timed is seconds
2
ON: If latched until code is entered. OFF: for timed
3
ON: If output should stop timing when a code is entered.
OFF: timed
4
ON: for inverted output
5
ON: disables output during listen-in
6 Reserved
7 Reserved
8 Reserved
Segment 2
(Circle Numbers To Program)
1 Partition
1
2 Partition
2
3 Partition
3
1
4 Partition
4