Segment 1 – Module number (default = 0)
Location 5, segment 1 contains the X-10 module number. Program a number from 0-15 to represent
the corresponding X-10 module number from the following table.
Module
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Segm. 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Segment 2 – House code (default = 0)
Location 5, segment 2 contains the X-10 house code. Program a number 0-15 to represent the
corresponding X-10 house code from the following table.
0 = A
4 = E
8 = I
12 = M
1 = B
5 = F
9 = J
13 = N
2 = C
6 = G
10 = K
14 = O
X-10
ADDRESS
CODES
3 = D
7 = H
11 = L
15 = P
LOCATION 6-13 - PROGRAMMING X-10 ADDRESS FOR OUTPUTS 2-9 (2 segments, numerical
data)
Locations 6 through 13 are used to program the X-10 address for outputs 2-9. Each location has 2
segments. Segment 1 contains the module number and segment 2 contains the house code. Refer to
the instructions in location 5, as well as the charts shown above and the programming worksheets.
NX-534E Programming worksheets
(Defaults are in
bold italic
text)
LOC
DESCRIPTION
DEFAULT
PROGRAMMING DATA
OPTION FLAGS (Circle numbers to program)
1
OFF: Line hold mode. ON: Call-back mode
2
OFF: Normal two-way. ON: Listen-in only
3
OFF: Automatic speaker lockout. ON: Speaker lockout disabled
4
Microphone A condition at start-up
5
Microphone B condition at start-up
6
ON: Call-in feature answering machine defeat enabled
7
ON: Enable levels 7 & 8
0
8 Reserved
1
CALL-BACK ACCESS CODE
10 = *, 11 = #, 12 = none, 13 thru 15 = any digit
1 2 3 4 5 6
2
LINE HOLD DIGIT
10 = *, 11 = #, 12 = none, 13 thru 15 = any digit
15 (F)
TIMING OPTIONS
1
Line hold timeout (10-255 seconds)
60
2
New trip hang-up time (1-255 seconds)
20
3 Call-back
window
(1-255 minutes)
5
3
4
Maximum number of digits during code entry (2-255)
12
Содержание NX-10