NX-10 Expander Installation Guide
65
8.
The keypad beeps once to accept the change and returns to
Outputs
.
Table 9.
NX-320-I output events
#
Event
#
Event
#
Event
Alarms
Arm/disarm
Misc
17
Alarm Memory
21
Armed
32
Code Entry
Tests
22 Disarmed
7 Program
Mode
3
Dyn Battery Test
23
Ready to Arm
0
Always On
Tampers
18 Entry
Keypads
25
Fire LED
19
Exit
29
Keypad Fire
11
Smoke Det Reset
20
Entry or Exit
30
Keypad Medical
8
Over-current
24
Not Ready to Arm
31
Keypad Panic
9
Box Tamper
Sirens
28 Keypad
Beeping
10
Siren Tamper
12
Burglary Siren
27
Chime
26
Fire Trouble
13
Fire Siren
Communications
1 Mains
Failure
14
Any
Siren
4 Listen-in
2
Low Battery
15
Fire Sir Steady
5
Line Seizure
16
Any Sir Temporal
6
Phone Line Fault
Note:
Faults on outputs are restored after a valid PIN is entered at the keypad.
Configuring features
You can configure testing and reporting features for the NX-320-I power module. The following
example enables a battery test which lasts for 60 minutes and sends a report to the central station
when a low battery condition occurs.
1
. Navigate with the
½¾
keys to
NX-320-I Power Modules>Power Module 84>Feature Select
and press
OK
.
2
. Scroll
to
Battery Test>Enabled
and press
OK
.
3
. The keypad beeps once to accept the change and returns to
Battery Test
.
4
. Scroll
to
Battery Test
Time
and press
OK
.
5
. Select
60
min.
and press
OK
. The keypad beeps once to confirm the change and returns to
Battery Test
Time
.
7
. Scroll
to
Reports>Low Battery>Yes
and press
OK
.
8
. The keypad beeps once to accept the change and returns to
Low Battery
.