Segment 3
Enabling the Schedules for the Onboard Relay Output
1
On if relay output follows Schedule 1.
2
On if relay output follows Schedule 2.
3
On if relay output follows Schedule 3.
4
On if relay output follows Schedule 4.
5
On if relay output follows Schedule 5.
6
On if relay output follows Schedule 6.
7
On if relay output follows Schedule 7.
8
On if relay output follows Schedule 8.
Segment 4
Door Options
1
On if locking mechanism is a Maglock or Drop Bolt.
2
On if access is allowed regardless of Armed status of the system.
3
No Unlock Latch. On if the door is not to be latched unlocked during an open schedule.
4
On if onboard relay output only triggers during an open schedule.
5
On if onboard relay output only triggers during a close schedule.
6
On if Forced Entry Alarm is logged.
7
On if access allowed without an RTE.
8
No armed Egress. On if the Egress input is to be disabled while the ProxPad partition is
armed.
Segment 5
Door Options (cntd..)
1
“On” when relay operation is inverted.
2
Disable relay operation when the ProxPad partition is disarmed.
3
Reserved.
4
Reserved.
5
Reserved.
6
Reserved.
7
Reserved.
8
Reserved.
•
Maglock/Drop Bolt: When a door zone is programmed and this option is checked, then the
relay output uses the different kind of logic for setting the lock. To prevent a door from
slamming shut due to a maglock or from not getting shut at all with a premature lock of a
drop bolt, the reader monitors the door zone and waits for the door to be shut for a couple of