8.
Press the relevant keys to include partition 2 in the alarms report and press
OK
.
9.
The keypad beeps once to accept the change and returns to Alarms.
10.
Navigate with the
½¾
keys to
Options>Reporting>Report Format
and select the format
relevant for your central station receiver.
11.
The keypad beeps once to accept the change and returns to
Report Format
.
12.
Navigate with the
½¾
keys to
E-mail Reporting>E-mail Server>Domain Name
and
press
OK
.
13.
Enter the domain name of the server to which reports are sent and press
OK
.
14.
The keypad beeps once to accept the change and returns to
Domain Name
.
15.
Scroll to
E-mail Server>IP Address
and press
OK
.
16.
Enter the IP address of the server to which reports are sent and press
OK
.
17.
The keypad beeps once to accept the change and returns to
IP Address
.
Configuring reporting options
The NX-590E TCP/IP module can send primary, backup and dual reports. The following steps
explain how to configure each type of report.
1.
Navigate with the
½¾
keys to
NX-590E>Options>Reporting
and press
OK
.
2.
To use another NX-590E receiver as backup, select
Receiver 2 as Backup>Enabled
and
press
OK
.
3.
To use the control panel as backup:
•
Select
Control Panel is Backup>Enabled
and press
OK
.
•
Enable autotest report on the control panel phone events and panel system events.
•
Ensure the reporting format used by the control panel is the same as that set in
Report
Format
.
4.
To configure dual reporting:
•
Select
Receiver 2 as Backup>Disabled
and press
OK
.
•
Select
Control Panel is Backup>Disabled
and press
OK
.
•
Enable all event categories on the control panel.
Configuring upload/download
To enable upload/download, you must configure the session initiation settings on the NX-590E
TCP/IP module and specify the PC IP address and port. The upload/download access code is set on
the control panel. The following example enables download sessions during test calls. The calls are
initiated from a central station (IP address 192.37.57.3) using the TCP/IP alarm port.
1.
Navigate with the
½¾
keys to
NX-590E>Up/Download
and press
OK
.
2.
Scroll to
Remote Initiated>Enabled
and press
OK
.
3.
The keypad beeps once to accept the change and returns to
Remote Initiated
.
4.
Scroll to
IP Address
and press
OK
.
5.
Enter
192.37.57.3
and press
OK
.