NX-10 Expander Installation Guide
159
Figure 23.
Mounting additional modules.
5.
Connect the control panel battery leads to the module, if required.
6.
Connect the battery and power up the panel.
7.
Close the housing.
Small polycarbonate housing
Small polycarbonate housing is adequate for systems with a just a single additional module installed
(usually the TCP/IP module). When expanding the small system, switching to the large
polycarbonate box may be required, since more modules cannot physically fit the smaller housing.
1.
Unscrew the holding screw in the polycarbonate housing.
2.
Open the box.
3.
Lift off the lid of the box.
If you are using an additional module:
4.
Connect the NetworX bus cables to the module.
5.
Connect the NetworX bus cables from the additional module to the panel. You can use
standard NetworX bus contacts or bus connectors.
6.
Clip-in the TCP/IP module inside the housing cover.
7.
Connect the Ethernet cable to the TCP/IP module (see instructions in the NX-590E
module manual).
8.
Connect the battery leads to the battery and power up the panel.
9.
Close the housing.
Содержание NX-10