05-2806A01, Rev. J
iNET Series Reference Manual
155
5.2 FUSE REPLACEMENT
An internal fuse protects the transceiver from over-current conditions or
an internal component failure. It should not be replaced until you are
certain you are in a safe (non-flammable) environment.
1. Disconnect the primary power source and all other connections to
the unit.
2. Place the radio
on its back and remove the four Phillips screws on
the bottom cover.
3. Carefully separate the top and bottom covers. There is a
fl
at ribbon
cable between the top cover’s LEDs and the unit motherboard. You
do not need to disconnect the ribbon cable.
4. Locate the fuse and fuse holder between the
COM1
port and the
power connector. See Figure 5-4 for details.
5. Loosen the fuse from the holder using a very small screwdriver. Use
a small pair of needle-nose pliers to pull the fuse straight up and
remove it.
6. Using an Ohmmeter, or other continuity tester, verify the fuse is
blown.
7. Install a new fuse by reversing the process.
Littelfuse P/N: 0454002; 452 Series, 2 Amp SMF Slo-Blo
GE MDS P/N: 29-1784A03
6
Data Set Ready (DSR)
In]<—
7
Request-to-Send (RTS)
Out]—>
8
Clear-to-Send (CTS)
In]<—
9
Unused
Table 5-3. COM2 Port, DB-9M/EIA-232 Interface
Pin
Functions
DTE
Содержание MDS iNET 900
Страница 12: ...2 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 32: ...22 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 122: ...112 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 134: ...124 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 136: ...126 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 160: ...150 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 162: ...152 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 172: ...162 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 180: ...170 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 186: ...I 6 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 188: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www gemds com 175 Science Parkway ...