05-2806A01, Rev. J
iNET Series Reference Manual
133
order to maintain compliance with FCC maximum limit of +36 dBi. If
other coaxial cable is used, the appropriate changes in loss figures must
be made.
NOTE:
The authority to operate the transceiver in the USA may be
void if antennas other than those approved by the FCC are
used. Contact your factory representative for additional
antenna information.
*Refer to Table 4-3 for allowable power settings of the transceiver for
each antenna type.
NOTE:
There is no minimum feedline length required when a 6 dBi
gain or less antenna is used, as the EIRP will never exceed 36
dBm which is the maximum allowed, per FCC rules. The
transceiver’s RF output power may only be adjusted by the
manufacturer or its sub-contracted Professional Installer.
The MDS iNET-II Transceiver is factory set to +29 dBm
power output to maintain compliance with the FCC’s Digital
Transmission System (DTS) Part 15 rules. These rules limit
power to a maximum of 8 dBm/3 kHz, thus the iNET-II Trans-
ceiver is factory set to +29 dBm. When calculating maximum
transceiver power output for iNET-II installations, use +29
dBm if antenna gain is 6 dBi or less. See How Much Output
Power Can be Used? on Page 135 for power control of higher
gain antennas.
4.1.6 How Much Output Power Can be Used?
The transceiver is normally supplied from the factory set for a nominal
+30 dBm (+29 dBm for iNET-II) RF power output setting; this is the
maximum transmitter output power allowed under FCC rules. The
power must be
decreased
from this level if the antenna system gain
exceeds 6 dBi. The allowable level is dependent on the antenna gain,
feedline loss, and the transmitter output power setting.
Table 4-2. Feedline Length vs. Antenna Gain*
(Required for Regulatory compliance)
Antenna
Gain (dBd)
Antenna
Gain (dBi)
Minimum Feedline
Length (Loss in dB)
EIRP Level @
Min. Length
Maxrad Antenna
Part No.
Unity (0 dB)
2.15 dBi
No minimum length
+32.15 dBm
Omni #MFB900
3 dBd
5.15 dBi
No minimum length
+35.15 dBm
Omni # MFB900
5 dBd
7.15 dBi
3.1 meters (1.2 dB)
+35.95 dBm
Omni # MFB900
6 dBd
8.15 dBi
9.1 meters (2.2 dB)
+35.95 dBm
Yagi # BMOY8903
9.2 dBd
11.34 dBi
25 meters (5.34 dB)
+36.00 dBm
Yagi OGB9-915
Содержание MDS iNET 900
Страница 12: ...2 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 32: ...22 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 122: ...112 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 134: ...124 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 136: ...126 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 160: ...150 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 162: ...152 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 172: ...162 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 180: ...170 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 186: ...I 6 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 188: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www gemds com 175 Science Parkway ...