With an iNET radio (non-iNET-II), a maximum of three zones
may be skipped to be compliant with FCC regulations.
2.5.4 Auto Data Rate Configuration Menu
The Auto Data Rate Configuration submenu is typically for use in envi-
ronments where signal quality is variable, and you wish to maintain the
highest possible over-the-air data rate as conditions change.
Invisible place holder
Figure 2-29. Auto Data Rate Submenu
•
ADR RSSI Threshold—
A specified received signal strength
value, which, if exceeded by the range of the
RSSI Delta
set-
ting, causes a data rate change in the transceiver. [
-50 to -100;
-87 dBm
]
•
ADR RSSI Delta—
A user-specified
difference
from the
RSSI
Threshold
figure which, if exceeded, causes a data rate change
in the transceiver. [
0-10; 5
]
•
ADR SNR Threshold—
A user-specified signal-to-noise ratio,
which, if exceeded by the range of the
SNR Delta
setting,
causes a data rate change in the transceiver. [
10-30; 26
]
•
ADR SNR Delta—
A user-specified
difference
from the
SNR
Threshold
figure which, if exceeded, causes a data rate change
in the transceiver. [
0-10; 2
]
NOTE:
In the description below, “high speed” refers to 512 kbps for
the iNET radio and 1 Mbps for the iNET-II radio.
“Standard speed” refers to 256 kbps for the iNET radio and
512 kbps for the iNET-II.
Содержание MDS iNET 900
Страница 12: ...2 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 32: ...22 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 122: ...112 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 134: ...124 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 136: ...126 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 160: ...150 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 162: ...152 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 172: ...162 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 180: ...170 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 186: ...I 6 iNET Series Reference Manual 05 2806A01 Rev J ...
Страница 188: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www gemds com 175 Science Parkway ...