MDS entraNET Start-Up Guide
05-4565A01, Rev. A
Invisible
place
holder
Figure 4. DC Power Connector
The transceiver must be used only with
negative-ground systems. Make sure the
polarity of the power source is correct. The
radio is protected from reverse polarity by
an internal diode and an on-board fuse.
Step 4—Configure the AP
The AP must be configured first, as Remote transceivers depend on the
AP beacon signal to achieve a connected (linked) state. For detailed
AP menu navigation instructions, refer to the
MDS entraNET System
Guide (05-4055A01)
.
a. Connect to the AP using a serial or Ethernet connection.
Console Terminal Connection
(recommended for first-time log-in)
To configure the AP using the serial
COM1
port, connect a PC to the
COM1
port on the radio and configure HyperTerminal with the fol-
lowing data parameters:
• 19200 bps
• 8 bits, no parity, one stop bit (8N1)
• hardware flow control disabled
• VT100 emulation
Telnet Connection Using the AP LAN Port
To configure the AP via its
LAN
port, connect a PC Ethernet port to the
AP with an Ethernet crossover cable, and start a telnet session to the
IP address of the AP. The default is 192.168.1.1.
b. Log in to the AP as follows:
Lead
Screws (2)
Binding
Wire Ports (2)
(Polarity: Left +, Right –)