Optimizing Spectral Doppler
LOGIQ 7 Online Help
5
-
103
Direction 2392536-100 Rev. 1
Audio Volume
Description
Controls audio output.
Adjusting
To adjust the audio, adjust the
Volume
control. The volume
defaults to the last Doppler audio volume setting.
Values
Usually, a one-third adjustment of the dial gives you the best
volume. The volume decreases/increases logarithmically.
Benefits
An audio representation of the flow within a vessel can be used
to evaluate proper probe angle and position.
Invert
Description
Vertically inverts the spectral trace without affecting the baseline
position.
Adjusting
To invert the spectral trace, press
Invert
. The plus (+) and minus
(-) signs on the velocity scale reverse when the spectrum is
inverted.
Positive velocities display below the baseline and to the left
speaker (as you face the system).
Positive velocities display below the baseline.
Values
Forward/reverse. The trace corresponds to flow direction
(positive flow is forward flow toward the probe or negative flow is
reverse flow away from the probe). The invert setting is returned
to the factory or user preset value when you change the
following: Probe, Exam Category, Exam Calcs, or New Patient.
In Triplex, both Color Flow and Doppler Mode velocity scales
are inverted.
Benefits
If you change the probe angle to accommodate anatomy, blood
flow still moves in the same direction, but the Doppler
information will be reversed. It is easier in cases like this to
invert the spectrum instead of reversing the probe orientation.
Affect on other
controls
The polarity of Doppler Audio is also reversed.
CAUTION
Audio sounds change rapidly, often abruptly. Increase the
volume in small steps to avoid startling the patient.
Содержание LOGIQ 7
Страница 4: ...i 2 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 This page intentionally left blank ...
Страница 16: ...i 14 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 28: ...Introduction 1 12 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 140: ...Preparing for an Exam 4 28 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 306: ...Scanning Display Functions 6 42 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 400: ...General Measurements and Calculations 7 94 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 418: ...Abdomen and Small Parts 8 18 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 644: ...Cardiology 10 128 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 688: ...Urology 12 8 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 698: ...Pediatrics 13 10 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 699: ...LOGIQ 7 Basic User Manual 14 1 Direction 2392206 100 Rev 1 Chapter 14 ReportWriter Describes how to generate reports ...
Страница 741: ...LOGIQ 7 Basic User Manual 15 1 Direction 2392206 100 Rev 1 Chapter 15 Recording Images Describes how to record images ...
Страница 779: ...Presets LOGIQ 7 Basic User Manual 16 3 Direction 2392206 100 Rev 1 Overview continued Figure 16 1 Utility Touch Panel ...
Страница 882: ...Customizing Your System 16 106 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...
Страница 928: ...Probes and Biopsy 17 46 LOGIQ 7 Online Help Direction 2392536 100 Rev 1 ...
Страница 974: ...User Maintenance 18 46 LOGIQ 7 Online Help Direction 2392536 100 Rev 1 ...
Страница 983: ...GE Medical Systems ...
Страница 984: ...1 2 LOGIQ 7 Basic User Manual Direction 2392206 100 Rev 1 ...