– 54 –
Oven Sensor and Door Switch Test
Note
: See
Lock Assembly
for an explanation of the door switch function.
Remove power from the oven.
1.
Make resistance measurements from the side of the sensor and the lock switch connector with exposed
2.
terminals.
The resistance measurements are made on the logic board at the connector listed on the chart below.
3.
If an abnormal reading is observed, wiggle the leads at the disconnect block. If there is any variation,
4.
replace the component.
Resistance Measurement Chart
Models
Circuit
Connector
Terminals
Ohms
Upper
Lower
JKS10
Oven Sensor
CN2
4 to 6
n/a
1080
Ω
@ Rm. Temp.
JKP30
JKP35
Oven Sensor
CN2
4 to 6
n/a
1080
Ω
@ Rm. Temp.
Door Unlatched
CN2
1 to 3
2 to 3
n/a
0
Ω
open
Door Latched
CN2
2 to 3
1 to 2
n/a
0
Ω
open
JKP55
JKP75
PK956
ZEK958
Oven Sensor
J3 (upper)
J4 (lower)
6 to 8
1 to 2
1080
Ω
@ Rm. Temp.
Door Unlatched
J3 (upper)
3 to 5
4 to 5
0
Ω
open
J4 (lower)
4 to 6
4 to 5
0
Ω
open
Door Latched
J3 (upper)
4 to 5
3 to 5
0
Ω
open
J4 (lower)
4 to 5
4 to 6
0
Ω
open
JKP70
PK916
ZEK938
Oven Sensor
CN2
6 to 8
n/a
1080
Ω
@ Rm. Temp.
Door Unlatched
CN2
3 to 5
4 to 5
n/a
0
Ω
open
Door Latched
CN2
4 to 5
3 to 5
n/a
0
Ω
open
JKP90
Oven Sensor
J1
4 to 6
n/a
1080
Ω
@ Rm. Temp.
Door Unlatched
CN2
1 to 3
2 to 3
n/a
0
Ω
open
Door Latched
CN2
2 to 3
1 to 3
n/a
0
Ω
open
Содержание JKS10
Страница 59: ...59 Continued Next Page Model JKP30 OVEN TEMP 1100 ROOM TEMP 2650 CLEAN TEMP...
Страница 60: ...60 Continued Next Page Model JKP35...
Страница 61: ...61 Continued Next Page Model JKP55...
Страница 62: ...62 Continued Next Page Models JKP70 PK916 ZEK938...
Страница 63: ...63 Continued Next Page Models JKP75 PK956 ZEK958...
Страница 64: ...64 Model JKP90 OVEN TEMP 1100 ROOM TEMP 2650 CLEAN TEMP ROOM TEMP ROOM TEMP RELAY COILS 650 24 VDC...
Страница 66: ...66...