Control Board Testing
The resistance of various components can be checked from the electronic oven control by the service
technician to quickly identify failed or improper operation of certain oven components.
Note
: Colored dots on relays match color of wire.
Hidden Bake Element
To test the hidden bake element, the
resistance should read approximately 27
Ω
between the orange wire at
DLB
and the
yellow wire at
BAKE
.
(See photo.)
Convection Element
To test the convection element, the
resistance should read approximately 22
Ω
between the orange wire at
DLB
and the
blue wire at
CONV
.
(See photo.)
Broil Element
To test the broil element, the resistance
should read approximately 17
Ω
between
the orange wire at
DLB
and the purple
wire at
BROIL
.
(See photo.)