– 51 –
Model JKP70, PK916, & ZEK938
TERMINALS
VOLTAGE
L1-N
120 VAC all the time
COM to N
120 VAC all the time
L1-L2
240 VAC all the time
L1-BA, L1-BR, L1-CV 120 VAC oven on, not calling
for heat. DBL relay K9
closed.
*OL-L1
120 Volts when light is on.
COM to MDL
120 Volts not locking or
unlocking, door closed.
**L1-CF
120 Volts when oven door is
closed, fan off.
*If the oven light is not working, make the following
checks:
• Check the oven light bulb to verify it works.
• The light comes on when the door is opened. Check
for 120VAC from OL terminal to L1. If 120 VAC is not
present, press the oven door switch in and out several
times, leaving the oven door open. Recheck for 120 VAC
from OL terminal to L1 with the oven door open. If
120 VAC is not present, replace the oven door switch.
• Close the oven door. Check for 120 VAC from OL
terminal to L1. If 120 VAC is present but the light does
not turn on, the light bulb is bad or there is a loose
connection in the wire harness. If 0 VAC, press
Oven
Light
key on key panel and retry. If still 0 VAC, check
the key panel. If the key panel is OK, replace the control. (If you hear a relay click when the
Oven Light
key
on the control panel is pressed, the key panel is working.)
**If the convection fan not running, make the following checks:
• Check the voltage from terminal CW and CCW to N on the control
―
it should always read 120 VAC in
Conv.
Bake
or
Convection Roast
modes.
• If the voltage OK, check the convection fan motor. It should read approx. 15–20
Ω
at room temperature.
Check to make sure the fan shaft is not rubbing on the liner.
• Check the door switch.
• Check the capacitor.
(
Continued Next Page
)
Model JKP90
TERMINALS
VOLTAGE
L1 to N
120 VAC all the time
CN104-3 to N
120 VAC when door locking/
unlocking.
CN104-4 to N
120 VAC when in Bake, Broil,
Clean, or Cool Down
*Lamp-L1
120 VAC when light is on
*If the oven light is not working, make the following
checks:
• Check the oven light bulb to verify it works.
• The light comes on when the door is opened. Check
for 120 VAC from CN104-1 terminal to L1. If 120 VAC
is not present, press the oven door switch in and out
several times, leaving the oven door open. Recheck
for 120 VAC from CN104-1 terminal to L1 with the
oven door open. If 120 VAC is not present, replace the
oven door switch.
• Close the oven door. Check for 120 VAC from CN104-1 terminal to L1. If 120 VAC is present but the light
does not turn on, the light bulb is bad or there is a loose connection in the wire harness. If 0 VAC, press
Oven
Light
key on the key panel and retry. If still 0 VAC, check the key panel. If the key panel is OK, replace the
control. (If you hear a relay click when the
Oven Light
key on the control panel is pressed, the key panel is
working.)
Содержание JKS10
Страница 59: ...59 Continued Next Page Model JKP30 OVEN TEMP 1100 ROOM TEMP 2650 CLEAN TEMP...
Страница 60: ...60 Continued Next Page Model JKP35...
Страница 61: ...61 Continued Next Page Model JKP55...
Страница 62: ...62 Continued Next Page Models JKP70 PK916 ZEK938...
Страница 63: ...63 Continued Next Page Models JKP75 PK956 ZEK958...
Страница 64: ...64 Model JKP90 OVEN TEMP 1100 ROOM TEMP 2650 CLEAN TEMP ROOM TEMP ROOM TEMP RELAY COILS 650 24 VDC...
Страница 66: ...66...