– 57 –
Line Voltage Testing
To test the line voltage at the board, the
black wire is L1, The white wire is neutral,
and the red wire is L2. The voltage should
be approximately 120 VAC between
L1 and N and approximately 240 VAC
between L1 and L2.
(See photo.)
Convection Fan Motor
To test the convection fan motor, the
resistance should read approximately 168
Ω
between the red wire at
CW
and the blue
wire at
CCW
.
(See photo.)
Sensor
To test the sensor, the resistance should
read approximately 1100
Ω
at room
temperature between the 2 white wires at
pin 6 and pin 8 on
CN2
.
(See photo.)