Installation Instructions
7
4
EXHAUST CONNECTION
LEVEL
SIDE-TO-SIDE.
2 LEVELING LEGS
LEVEL
FRONT-TO-BACK.
DUCT TAPE OR
DUCT CLAMP
DUCT TAPE OR
DUCT CLAMP
4" METAL DUCT CUT
TO PROPER LENGTH
EXTERNAL DUCT
OPENING
For straight line installation, connect
the dr
y
er exhaust to the external
exhaust hood using duct tape or
clamp.
5
LEVELING AND STABILIZING YOUR APPLIANCE
STANDARD REAR EXHAUST
Level and stabilizing your appliance
&DUHIXOO\PRYHWKHDSSOLDQFHWRLWV¿QDOORFDWLRQ*HQWO\URFN
the appliance into position. It is important not to damage the
UXEEHUOHYHOLQJOHJVZKHQPRYLQJ\RXUDSSOLDQFHWRLWV¿QDO
location.
Damaged
legs can increase appliance vibration. It
PD\EHKHOSIXOWRVSUD\ZLQGRZFOHDQHURQWKHÀRRUWRKHOS
PRYH\RXUDSSOLDQFHWRLWV¿QDOSRVLWLRQ
Note:
Do not use washer cover to lift the unit.
2. To ensure the appliance is level and solid on all four legs,
WLOW WKH DSSOLDQFH IRUZDUG VR WKH UHDU OHJV DUH RȺ WKH
ground. Gently set the appliance back down to allow the
rear legs to self adjust.
:LWKWKHDSSOLDQFHLQLWV¿QDOSRVLWLRQSODFHDOHYHORQWRS
of back part of the washer lid and check it side to side,
then check front to back. Screw the front leveling legs up
or down to ensure the appliance is resting solid on all four
OHJV QR URFNLQJ RU WKH DSSOLDQFH VKRXOG H[LVW WXUQ WKH
lock nuts on each leg up toward the base of the unit and
snug with a wrench.
Note:
Keep the leg extension at minimum to prevent excessive
vibration. The farther out legs are extended, the more the unit
will vibrate.
STANDARD REAR EXHAUST
9HQWHGDERYHÀRRUOHYHO
(/%2:+,*+/<
5(&200(1'('
5(&200(1'('
&21),*85$7,21
720,1,0,=(
(;+$867%/2&.$*(
NOTE:
ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING
WARNING -
TO REDUCE THE
RISK OF FIRE OR PERSONAL INJURY:
• This appliance must be exhausted to the outdoors.
• Use only 4” rigid metal ducting for the home exhaust
duct.
8VH RQO\ µ ULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDO
VHPLULJLGRUIRLOW\SHGXFWWRFRQQHFWWKHGU\HUWRWKH
home exhaust duct. It must be installed in accordance
with the instructions found in “Connecting The Dryer
To House Vent” on page 8 of this manual.
• Do not terminate exhaust in a chimney, a wall, a ceiling,
JDV YHQW FUDZO VSDFH DWWLF XQGHU DQ HQFORVHG ÀRRU
or in any other concealed space of a building. The
accumulated lint could create a
potential
¿UHKD]DUG
1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFWZLWK
a kitchen exhaust system. A combination of grease
DQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW
length table. Longer ducts can accumulate lint,
FUHDWLQJDSRWHQWLDO¿UHKD]DUG
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
ZLOOFDXVHOLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UH
KD]DUG
• Do not assemble ductwork with any fasteners that
extend into the duct. These fasteners can accumulate
OLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
• Do not obstruct incoming or exhausted air.
• Provide an access for inspection and cleaning of the exhaust
system, especially at turns and joints. Exhaust system shall
be inspected and cleaned at least once a year.
THIS DRYER COMES READY FOR REAR
EXHAUSTING. IF SPACE IS LIMITED, USE
THE INSTRUCTIONS IN SECTION 6 TO
EXHAUST DIRECTLY FROM THE SIDES OR
BOTTOM OF THE CABINET.